Value Range
•
UDP
•
TCP
Default Value
UDP
Configuration File Reference
4.6.2.9 Timer Settings
T1 Timer
Description
Selects the default interval, in milliseconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
•
250
•
500
•
1000
•
2000
•
4000
Default Value
500
Configuration File Reference
T2 Timer
Description
Selects the maximum interval, in seconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
•
2
•
4
•
8
•
16
•
32
Default Value
4
Configuration File Reference
Timer B
Description
Specifies the value of SIP timer B (INVITE transaction timeout timer),
in milliseconds. For details, refer to RFC 3261.
Value Range
250–64000
Default Value
32000
Configuration File Reference
94
Administrator Guide
Document Version 2012-07
Section 4 Web User Interface Programming