REG_INTERVAL_RATE_n
Parameter Name Example
REG_INTERVAL_RATE_1
,
REG_INTERVAL_RATE_2
, …,
REG_INTERVAL_RATE_6
Value Format
Integer
Description
Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same dialog.
Value Range
1–100
Default Value
90
SIP_SESSION_TIME_n
Parameter Name Example
SIP_SESSION_TIME_1
,
SIP_SESSION_TIME_2
, …,
SIP_SESSION_TIME_6
Value Format
Integer
Description
Specifies the length of time, in seconds, that the unit waits before
terminating SIP sessions when no reply to repeated requests is
received. For details, refer to RFC 4028.
Value Range
0, 60–65535 (0: Disable)
Default Value
0
Web User Interface Reference
Supports Session Timer (RFC 4028) (Page 96)
SIP_SESSION_METHOD_n
Parameter Name Example
SIP_SESSION_METHOD_1
,
SIP_SESSION_METHOD_2
, …,
SIP_SESSION_METHOD_6
Value Format
Integer
Description
Selects the refreshing method of SIP sessions.
Value Range
0–2
–
0: reINVITE
–
1: UPDATE
–
2: AUTO
Default Value
0
DSCP_SIP_n
Parameter Name Example
DSCP_SIP_1
,
DSCP_SIP_2
, …,
DSCP_SIP_6
Value Format
Integer
Description
Selects the DSCP level of DiffServ applied to SIP packets.
Value Range
0–63
Document Version 2012-07
Administrator Guide
193
Section 5 Configuration File Programming
Summary of Contents for KX-UT670
Page 14: ...14 Administrator Guide Document Version 2012 07 Table of Contents ...
Page 226: ...226 Administrator Guide Document Version 2012 07 Section 8 Backup and Restore ...
Page 230: ...230 Administrator Guide Document Version 2012 07 Section 9 Resetting the Unit ...
Page 236: ...236 Administrator Guide Document Version 2012 07 Section 10 Troubleshooting ...
Page 239: ...Section 12 Appendix Document Version 2012 07 Administrator Guide 239 ...
Page 242: ...242 Administrator Guide Document Version 2012 07 Section 12 Appendix ...
Page 243: ...Index Document Version 2012 07 Administrator Guide 243 ...
Page 249: ...Document Version 2012 07 Administrator Guide 249 Notes ...