CODEC_PRIORITYx_n
For details about parameter names that include lower-case letters (e.g., "_n", "y", "x", or "m"), see
"4.2.1 Configuration File Parameters".
Value Format
INTEGER
Description
Specifies the priority order for the codec.
Note
•
The "x" character in the parameter title should be changed to
one of the following numbers, according to the codec to be
changed.
–
0
: G.722
–
1
: PCMA
–
2
: –
–
3
: G.729A
–
4
: PCMU
–
5
: Opus
•
For codec setting examples, see
.
Value Range
1–255
Default Value
1
Web User Interface Reference
•
•
•
•
•
CODEC_G711_REQ
Value Format
INTEGER
Description
Specifies whether to automatically select "
PCMU
" as the codec when a
codec other than "
PCMU
" is selected.
Value Range
•
0: Do not set "PCMU"
•
1: Set "PCMU"
Default Value
1
OPUS_BAND_TYPE_n
For details about parameter names that include lower-case letters (e.g., "_n", "y", "x", or "m"), see
"4.2.1 Configuration File Parameters".
Value Format
INTEGER
Description
Specifies the band type of the Opus codec.
4.26 CODEC Settings
Document Version: 2020-04
Administrator Guide