2.2 Installation of the Hybrid IP-PBX
56
Installation Manual
2.2.10 Surge Protector Installation
Overview
A massive electrical surge can be caused if lightning strikes a telephone cable 10 m (33 ft) above ground,
or if a telephone line comes into contact with a power line. A surge protector is a device that is connected
to a CO line to prevent potentially dangerous electrical surges from entering the building via the CO line and
damaging the Hybrid IP-PBX and connected equipment.
To protect the system from electrical surges, we strongly recommend connecting the system to a surge
protector that meets the following specifications:
•
Surge arrestor type: 3-electrode arrestor
•
DC spark-over voltage: 230 V
•
Maximum peak current: at least 10 kA
Additionally, proper grounding is very important for the protection of the system (refer to "2.2.5 Frame
Ground Connection").
Many countries/areas have regulations requiring surge protection. Be sure to comply with all applicable
laws, regulations, and guidelines.
Installation
CS
Extn.
Extn. Extn. Extn.
SLT
PT
CO Line
CO Line
CO Line
Extn.: Extension line
Surge
Protector
Terminal
Board
Hybrid
IP-PBX
Frame
Ground
Ground
Summary of Contents for KX-TDA50
Page 5: ...Installation Manual 5 SAVE THESE INSTRUCTIONS ...
Page 122: ...2 11 Starting the Hybrid IP PBX 122 Installation Manual ...
Page 132: ...3 3 Installation of the Hybrid IP PBX PC Programming Software 132 Installation Manual ...
Page 150: ...4 1 Troubleshooting 150 Installation Manual ...
Page 151: ...Installation Manual 151 Section 5 Appendix ...
Page 154: ...5 1 Revision History 154 Installation Manual ...
Page 155: ...Installation Manual 155 Index ...
Page 158: ...Index 158 Installation Manual ...