background image

Section  3

Starting the PBX

Getting Started

19

Summary of Contents for KX-TDA150BR

Page 1: ...d IP PBX Getting Started Thank you for purchasing a Panasonic Hybrid IP PBX Please read this manual carefully before using this product and save this manual for future use KX TDA150 PDMPR Software File Version 5 1000 or later ...

Page 2: ...ing the Option Units 12 2 4 Installing the Trunk Cards 13 2 5 Installing the Extension Cards DLC8 DLC16 MCSLC16 MCSLC24 16 2 6 Connecting Extensions 16 2 7 Frame Earth Connection 17 3 Starting the PBX 19 3 1 Starting the PBX 20 4 Customising the PBX 21 4 1 Connecting the PC 22 4 2 Installing the Maintenance Console 22 4 3 Programming the PBX 23 5 Confirming the Connection 29 5 1 Making Calls 30 2 ...

Page 3: ...Section 1 Before Installation Getting Started 3 ...

Page 4: ...ple and prevent damage to property The notices are classified as follows according to the severity of injury or damage WARNING This notice means that misuse could result in death or serious injury CAUTION This notice means that misuse could result in injury or damage to property 4 Getting Started 1 1 Safety Notices ...

Page 5: ... Trunk E1 Line Digital Trunk E1 KX TDA0188 T1 KX TDA0187 E M Line E M Line E M Line E M8 KX TDA0184 DID8 KX TDA0182 PSU Installed by default OPB3 KX TDA0190 DPH4 KX TDA0161 DPH2 KX TDA0162 ECHO16 KX TDA0166 MSG4 KX TDA0191 ESVM2 KX TDA0192 ESVM4 KX TDA0194 EIO4 KX TDA0164 Voice Processing System CS PS CSIF4 KX TDA0143 CSIF8 KX TDA0144 PC LAN CTI Server CTI LINK KX TDA0410 IP EXT16 KX TDA0470 IP PT...

Page 6: ... 1 AC Cord 1 Screw A 3 Screw B Black 2 Anchor Plug 3 SD Memory Card 1 Metal Bracket 1 Ferrite Core for the DMPR card 1 2 1 The larger of the two ferrite cores is used for the RJ45 cable The smaller of the two ferrite cores is used for the RJ11 cable s 6 Getting Started 1 3 Unpacking ...

Page 7: ...0 series ø 0 5 mm 229 m for DSS Console The maximum length of the cable may vary depending on the type of cable and installation conditions ü An RS 232C or USB cable for PC connection ü Connectors Amphenol RJ45 BNC for trunk and extension connections Note Use a shielded twisted pair cable for the Amphenol connector Use a twisted pair cable for the RJ45 connector Getting Started 7 1 3 Unpacking ...

Page 8: ...8 Getting Started 1 3 Unpacking ...

Page 9: ...Section 2 Installation Getting Started 9 ...

Page 10: ...cover Turn the screw anticlockwise to loosen 2 Slide the front cover to the right until it stops then lift the front cover Closing the Front Cover 1 Hook the front cover onto the shelf line up the protrusions on the cover with the receptacles on the shelf then slide the front cover to the left until it locks 10 Getting Started 2 1 Opening Closing the Front Cover ...

Page 11: ...sses of the PBX and all the customer data The SD Memory Card must be inserted before startup DMPR Card SD CARD 2 SD CARD 4 5 SD CARD SD Memory Card 3 1 CAUTION Do not remove the SD Memory Card while power is supplied to the PBX Doing so may cause the PBX to fail to start when you try to restart the system Getting Started 11 2 2 Inserting the SD Memory Card to the DMPR Card ...

Page 12: ...touch ground or wear an earthing strap Make sure the screws are tightened to earth the card securely Installing the Trunk Extension Cards 1 Insert the card along the guide rails 2 Holding the card as shown below push the release lever in the direction of the arrow so that the card engages securely with the connector on the back board 3 Turn the 2 screws clockwise to fix the card in place Guide Rai...

Page 13: ...ing the Blank Slots in 2 2 6 Installing Removing the Optional Service Cards of the Installation Manual 2 4 Installing the Trunk Cards LCOT4 LCOT8 LCOT16 CLCOT8 Card Example LCOT 16 Card Amphenol To trunk Accessories included Screws 2 User supplied not included Amphenol connector Getting Started 13 2 4 Installing the Trunk Cards ...

Page 14: ...ite core s 1 BRI4 card or 2 BRI8 card User supplied not included RJ45 connector CAUTION Connect these optional service cards to the trunk through an NT1 do not connect to the U interface of the trunk directly Notice When connecting the RJ45 connector attach the included ferrite core Note LINE 5 to LINE 8 are for BRI8 card only These optional service cards have 100 W of terminal resistance For use ...

Page 15: ...trunk through an NT1 do not connect to the U interface of the trunk directly Notice When connecting the RJ45 connector attach the included ferrite core Note In some countries areas the PRI30 card must not be connected to the Public Switched Telephone Network Use only 1 type of connector RJ45 or BNC for connection of PRI30 card RJ45 and BNC cannot be used simultaneously Set the termination switch t...

Page 16: ...sories included Screws 2 Ferrite core 1 User supplied not included Amphenol connector Note Attach the included ferrite core to the cable 2 6 Connecting Extensions Example KX T7600 Series DPT Pin Assignments To extension card RJ11 TO MAIN UNIT PABX KX T7000 Series SLT T R DPT and DSS Console H L H L 16 Getting Started 2 6 Connecting Extensions ...

Page 17: ... the PBX from the bad effects of external noise in the case of a lightning strike The earthing wire of the AC cable has an effect against external noise and lightning strikes but it may not be enough to protect the PBX A permanent connection between earth and the earth terminal of the PBX must be made CAUTION For earthing wire green and yellow insulation is required and the cross sectional area of...

Page 18: ...18 Getting Started 2 7 Frame Earth Connection ...

Page 19: ...Section 3 Starting the PBX Getting Started 19 ...

Page 20: ...he SD Memory Card slot of the DMPR card before startup Note The PBX will continue to be powered even if the power switch is turned OFF 1 Slide the System Initialise Switch to the INIT position INIT NORMAL System Initialise Switch RUN Indicator To AC Outlet 2 Plug the AC power cord into the PBX and an AC outlet and turn on the PBX The RUN indicator will flash 3 While the RUN indicator is flashing s...

Page 21: ...Section 4 Customising the PBX Getting Started 21 ...

Page 22: ...rame of the PC using an earthing wire in order to prevent difference in the electrical potentials 4 2 Installing the Maintenance Console For the system requirements of the PC e g operating system hardware specifications refer to 3 3 1 Installing and Starting the Maintenance Console in the Installation Manual Note Make sure to install and use the latest version of the Maintenance Console To connect...

Page 23: ...al information which includes updates to this and other manuals b Click OK to close this window 4 a Enter the Installer Level Programmer Code default INSTALLER b Click OK 5 Click Connect 6 a Select KX TDA150 from PBX Model Note Depending on the type of Maintenance Console used you may not be required to select a PBX model If KX TDA150 is not shown select KX TDA100D b Select the USB or RS 232C tab ...

Page 24: ...8 Follow the instructions of the Quick Setup wizard and assign the basic items Quick Setup The system menu appears You may now begin programming the PBX 24 Getting Started 4 3 Programming the PBX ...

Page 25: ...Configuration from the menu bar 3 a Click Check to turn on the BRI card b Click OK 4 a Enter the subscriber number for the desired ports in Subscriber b Click Execute Note Network settings are automatically set c Click Check Box of the desired ports d Click Data Apply e Click Close 5 a Under Configuration click Slot b Move the mouse pointer over the BRI card then click INS to set the card to in se...

Page 26: ... trunk users DDI Setting 1 Under CO Incoming Call click DDI DID Table 2 Configure the settings as required 3 Click OK For ISDN trunk users MSN Setting 1 Under CO Incoming Call click DIL Table Port Settings 2 Click the DDI DID TIE MSN tab 3 Set the Distribution Method of the desired ports to MSN 4 Click OK 5 Click MSN Table 6 Click the MSN tab 7 Configure the settings as required 8 Click OK 26 Gett...

Page 27: ...en click Port Property 5 For DPT Type set the Type to DSS and assign the Location No 6 Click OK 7 Under Extension click DSS Console 8 Select the desired pair extension number from Pair Extension 9 Assign features to flexible buttons as required 10 Click OK 11 Under Configuration click Slot 12 Move the mouse pointer over the card to display the menu of options 13 Click INS to set the card to in ser...

Page 28: ...28 Getting Started 4 3 Programming the PBX ...

Page 29: ...Section 5 Confirming the Connection Getting Started 29 ...

Page 30: ...l another extension Off hook Talk Dial extension number extension no To call an outside party Off hook Talk Dial outside phone number Enter automatic line access number 9 0 outside phone no 30 Getting Started 5 1 Making Calls ...

Page 31: ...Getting Started 31 Notes ...

Page 32: ...right This material is copyrighted by Panasonic System Networks Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic System Networks Co Ltd Panasonic System Networks Co Ltd 2011 PNQX3911ZA DD0411KK0 ...

Reviews: