1.3 Specifications
1.3.1 General Description
Control Bus
Original bus (16-bit, 8 MHz, 10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slots)
Switching
Non-blocking
Power Input
100 V AC to 130 V AC; 2.8 A/200 V AC to 240 V AC; 1.7 A; 50
Hz/60 Hz
External Battery
+36 V DC (+12 V DC
´
3, recommended maximum capacity is
28 Ah)
Maximum Power Failure Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
W
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
Conference Call Trunk
From 10
´
3-party conference call to 4
´
8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface
Port
RS-232C
1 (maximum 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1-pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
PT-interface CS (High-density)
4-pair wire (D1, D2)
DSS Console and Add-on Key
Module
1-pair wire (D1, D2)
Dimension
334 mm (W)
´
390 mm (H)
´
270 mm (D)
22
Installation Manual
1.3.1 General Description
Summary of Contents for KX-TDA150
Page 23: ...Weight when fully mounted Under 12 kg Installation Manual 23 1 3 1 General Description ...
Page 36: ...C Power Switch D Earth Terminal E AC Inlet 36 Installation Manual 2 2 2 Names and Locations ...
Page 136: ...136 Installation Manual 2 11 1 Starting the PBX ...