2.2 Installation of the Hybrid IP-PBX
42
Installation Manual
2.2.4
Installing/Replacing the Power Supply Unit
Function
Accessory and User-supplied Items
Accessory (included):
Screws × 4, AC power cord × 1
User-supplied (not included):
grounding wire
Note
For details about frame ground connection, refer to "2.2.5 Frame Ground Connection".
Safety Instructions
Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950,
CAN/CSA-C22.2 No.60950, and AS/NZS60950; therefore a protective earth connection exists between the
mains outlet ground and the PSU case. To ensure the PBX chassis is safely grounded, it is essential that
the PSU case be securely fastened to the PBX chassis with the 4 screws provided with each PSU.
When installing or replacing PSU, basic safety precautions should always be followed to reduce the risk of
fire, electric shock and injury to persons, including the following:
1.
Never install or replace PSU during a lightning storm.
2.
Never install or replace PSU in wet locations.
3.
Never install or replace PSU unless at least 20 s has elapsed after the AC supply is disconnected.
PSU Type
Lower/Upper Input Voltage Range
Current
Input Frequency
PSU-S
(for KX-TDA100)
Lower: 100 V AC to 130 V AC
1.4 A
50 Hz or 60 Hz
Upper: 200 V AC to 240 V AC
0.8 A
PSU-M
(for KX-TDA100/200)
Lower: 100 V AC to 130 V AC
2.5 A
Upper: 200 V AC to 240 V AC
1.4 A
PSU-L
(for KX-TDA200)
Lower: 100 V AC to 130 V AC
5.1 A
Upper: 200 V AC to 240 V AC
2.55 A
AC Inlet
Power Switch
AC Inlet
Power Switch
PSU-S
PSU-M/PSU-L
Ground Terminal
Ground Terminal
Summary of Contents for KX-TDA100 KX-TDA200
Page 34: ...1 4 Specifications 34 Installation Manual ...
Page 156: ...2 12 Starting the Hybrid IP PBX 156 Installation Manual ...
Page 184: ...4 1 Troubleshooting 184 Installation Manual ...
Page 185: ...Installation Manual 185 Section 5 Appendix ...
Page 188: ...5 1 Revision History 188 Installation Manual ...
Page 189: ...Installation Manual 189 Index ...
Page 193: ...Index Installation Manual 193 ...