Station Features and Operation (DPT/SLT)
276
User Manual
4.3.87
Walking COS
Allows you to use your calling privileges (Class of Service) at another extension. You may
override restrictions which may be set at the extension.
Making a call
Conditions
•
Class of Service (COS) programming is used to define the features which are allowed for a
group of extensions. Each extension is assigned a COS number. The programmable items
are as follows.
a)
Outgoing call restriction level (Day mode / Night mode) – 1 through 8
b)
Restriction of an outside call duration
c)
Transfer a call to an outside party
d)
Forward a call to an outside party
e)
Executive Busy Override
f)
Executive Busy Override Deny
g)
Override Do Not Disturb of the called extension
Any Telephone
Enter the Walking COS
password (4 through 7
digits).
Walking COS password
extension no.
Dial the phone
number.
phone no.
Lift the handset
or press
SP-PHONE/MONITOR.
Confirmation
tone and
dial tone
At another extension;
Dial your extension
number.
Dial 47.
Hang up or press
SP-PHONE/MONITOR.
4
7
<PT Display Example>
your extension
number
Set COS of Exxxx
You must dial a line access
code (9 or 81 through 88)
or press the CO button.
The COS level of the extension
returns to the original level.
Summary of Contents for KX-TD816C
Page 2: ...2 User Manual Thank you for purchasing the Panasonic Telephone System ...
Page 14: ...Table of Contents 14 User Manual ...
Page 68: ...Station Programming 68 User Manual ...
Page 69: ...User Programming User Manual 69 Section 3 User Programming ...
Page 346: ...Station Features and Operation DPT SLT 346 User Manual ...
Page 363: ...APPENDIX User Manual 363 Section 6 APPENDIX ...
Page 379: ...Index 379 Section 7 Index ...
Page 383: ...Index 383 ...