3.1
DECT Programming
298
DECT Programming
3.1
DECT Programming
[020]
PS Flexible Button Assignment
Description
Used to determine how the flexible CO buttons are used on PSs.
Selection
•
PS registration number:
KX-TD816 – 01 through 16
KX-TD1232 – 01 through 64
•
Flexible CO button number: 1 through 3
•
Button Code (plus parameter, if required)
Button Code
Parameter
0 (Single-CO)
TD816: 01 through 16 (CO line number)
TD1232: 01 through 54 (CO line number)
1 (DSS)
2 through 4 digits (Extension number)
2 (One-Touch)
24 digits max. (Telephone number)
3 (Message Waiting)
None
4 (FWD/DND)
None
5 (Save)
None
6 (Account)
None
7 (Conference)
None
80 (Log-In/Log-Out)
2 through 4 digits (Hunting group extension number)
82 (Voice Mail Transfer)
2 through 4 digits (Voice mail extension number)
83 (Two-Way Record)*
2 through 4 digits (Voice mail extension number)
84 (Two-Way Transfer)*
2 through 4 digits (Voice mail extension number)
8# (One-Touch Dialling with Auto Hold)
24 digits max. (Telephone number)
9 (Terminate)
None
(Loop-CO)
None
# (Group-CO)
1 through 8 (CO line group number)
* Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone
capable Panasonic Voice Processing System (one that supports digital proprietary telephone
integration; e.g.KX-TVP200).
Summary of Contents for KX-TD1232NE
Page 2: ...2 ...
Page 8: ...8 Table of Contents ...
Page 9: ...General Instructions 9 Section 1 General Instructions ...
Page 26: ...1 5 Example of Programming 26 General Instructions ...
Page 27: ...General Programming 27 Section 2 General Programming ...
Page 96: ...2 2 System Programming 96 GeneralProgramming Feature References Charge Fee Reference ...
Page 162: ...2 5 CO Line Programming 162 GeneralProgramming Feature References Intercept Routing ...
Page 171: ...2 5 CO Line Programming General Programming 171 Feature References Display Call Information ...
Page 208: ...2 6 COS Programming 208 GeneralProgramming Toll Restriction ...
Page 245: ...2 7 Extension Programming General Programming 245 Feature References Data Line Security ...
Page 297: ...DECT Programming 297 Section 3 DECT Programming ...
Page 324: ...3 1 DECT Programming 324 DECT Programming Feature References Department Codes ...
Page 335: ...3 1 DECT Programming DECT Programming 335 Display Call Information ...
Page 339: ...Default Values 339 Section 4 Default Values ...
Page 350: ...350 Default Values 682 Radio Information Data Clear Not applicable Program Default ...
Page 351: ...Default Values 351 ...