4.2
System Programming
E&M Signal Assignment
129
37
Description
Assigns the E&M signal. There are three signals available:
Continuous: Continuous E&M (Wink/Immediate)
Pulsed Ans: Pulsed E&M with Answer Signal (Wink only)
Pulsed No Ans: Pulsed E&M without Answer Signal (Wink only)
Selection
Continuous / Pulsed Ans / Pulsed No Ans
Default
Continuous
Programming
1.
Enter 129.
Display: E&M Signal
2.
Press NEXT.
Display example:Continuous
3.
Keep pressing SELECT until the desired selection is
displayed.
4.
Press STORE.
5.
Press END.
Conditions
• If you select “Pulsed Ans” or “Pulsed No Ans”, you must select “Wink”
as the start type.