8.4.
Check Point (Charger Unit)
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
)
Charging Check
-
1. Connect Charge Contact 12
Ω
/2W resistor between and charge-.
2. Measure and confirm voltage across the resistor is 3.10V ± 0.2V.
D2, R2, R1
Note:
After the measuring, sock up the solder of TP.
The connection ofadjustment equipment is as shown in
Adjustment Standard (Charger Unit)
(P.34).
8.5.
Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
8.5.1.
Flow Solder Side View
TP3
TP4
R2
D2
R1
A
TP2
TP1
KX-TCD800 SERIES
PQLV30040ZA
PQUP11348Z
PbF
DC POWER
+6.0V
TP1
TP2
(A)
Digital
Volt Meter
12
Ω
/2W
(+)
(-)
(+)
(-)
Note:
(
A
) is referred to
Check Point (Charger Unit)
(P.34)
34