Items
Adjustment
Point
Procedure*
(I)*
BBIC Clock
Adjusment
CLK
1. Execute the command "conttx".
2. Adjust the frequency of CLK executing the command "setfreq xx (where xx is the
value)" so that the reading of the frequency counter is 10.368000MHz ± 10Hz.
(J)
*
Transmitted
Power
Confirmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: PP
-RFPI: 0102030408
-Traffic Carrier: 5
-Traffic Slot: 4
-Mode: Loopback
-RF LEVEL = -70dBm
2. Execute the command "regcmd60 01 02 03 04 08".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm.
(K)
*
Modulatoin
Check and
Adjusment
-
Follow steps 1 to 3 of (J) above.
4.Confirm that the B-Field Modulation is 360kHz/div ~ 380kHz/
div using data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the
command "Readmod" and "wrtmod xx", where xx is the value.)
32
Summary of Contents for KX-TCA155CE
Page 10: ...7 3 Key Lock You can lock the dialling buttons while the PS is in idle status 10 ...
Page 17: ...10 DISASSEMBLY INSTRUCTIONS 10 1 Handset 17 ...
Page 21: ...Cross Reference 21 ...
Page 41: ...meter 2 Put the probes at the receiver terminals as shown below 41 ...
Page 66: ...26 CABINET AND ELECTRICAL PARTS LOCATION CHARGER UNIT 66 ...
Page 67: ...27 ACCESSORIES AND PACKING MATERIALS 67 ...
Page 68: ...28 TERMINAL GUIDE OF ICS TRANSISTORS AND DIODES 28 1 Handset 68 ...
Page 77: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A DC Power Supply 6V ...
Page 85: ...PbF D1 J1 CIRCUIT BOARD CHARGER UNIT Component View ...
Page 86: ...PbF R1 R2 TP4 TP1 TP2 TP3 CIRCUIT BOARD CHARGER UNIT Flow Solder Side View ...
Page 89: ...IC3 IC2 IC1 IC10 PbF Marked ...
Page 91: ...PbF D1 J1 Marked PbF R1 R2 TP4 TP1 TP2 TP3 Marked Component View Flow Solder Side View ...