9.32 PBX Configuration—[1-1]
Configuration—Slot—Expansion Unit1/Expansion
Unit2/Expansion Unit3
Settings for Expansion Units connected to the KX-NS300 over a stacking connection can be programmed.
Click
Expansion Unit1
,
Expansion Unit2
or
Expansion Unit3
on the
Slot
screen to view the physical card
shelf of the Expansion Unit.
Note
•
Expansion Units must first be pre-installed before they can be programmed. For details, see
To
pre-install PBXs connected to the EXP-M card
.
•
For information about hardware configuration restrictions and conditions for Expansion Units, refer to
To install a new physical card in an Expansion Unit
1.
Click on the name of the card to install in the list on the right. An image of the card will be displayed, and
information about the card will be shown.
2.
Click and drag the image of the card to the slot, and release it. The card will move into the slot space.
3.
Click
OK
to confirm.
To change the status (INS/OUS) of an Expansion Unit
1.
Move the mouse pointer over the
Shelf Status
button. A menu will be shown under the mouse pointer.
2.
Select the desired status:
•
Click
INS
to set the shelf to in-service status.
•
Click
OUS
to set the shelf to out-of-service status.
To remove an Expansion Unit from the EXP-M card
1.
Move the mouse pointer over the
Shelf Status
button. A menu will be shown under the mouse pointer.
2.
Click
Delete
. The Expansion Unit will be deleted from the system and the corresponding shelf button will
become greyed out.
Note
The Expansion Unit must be set to OUS before it can be deleted.
Programming cards installed in an Expansion Unit
You can access the card properties and port properties of the physical cards installed in a Expansion Unit
using the KX-NS300 Web Maintenance Console Interface. The settings, setting values, and other information
is similar to programming using the Unified PC Maintenance Console. Refer to the PC Programming Manual
of the Expansion Unit PBX for programming information.
Programming Card Properties for cards installed in Expansion Units
For your reference, the following information is included on each Card Property screen for cards installed in
Expansion Units:
Shelf
: The shelf number of the EXP-M card Expansion Unit connection:
•
2: Expansion Unit1
PC Programming Manual
341
9.32 PBX Configuration—[1-1] Configuration—Slot—Expansion Unit1/Expansion Unit2/Expansion Unit3
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...