2.1 Introduction
2.1.1 Web Maintenance Console Accounts
User account levels
Access to Web Maintenance Console requires a login name and password, which are assigned to accounts
in the PBX. Also, access to Web Maintenance Console is controlled by different levels of authorisation. The
Installer level is the highest authorisation level. There are also two levels for end users, Administrators and
Users. The usage for each level and number of accounts available for each level are as follows:
Level
Description
Number of Accounts
Installer
For dealers and system installers
1
User
(Administrator)
For on-site managers
8
User (User)
For end users
492
Differences between user levels
•
Installer
The installer level account is the highest authorisation account of the three levels. This account level is to
be used by dealers or system installers. All system programming settings are available, and this account
is used for overall system installation and maintenance. The installer level can be used to programme
which menus in Web Maintenance Console are accessible by Administrator accounts.
•
User (Administrator)
Administrator accounts are for general maintenance of users and user settings. This account level is used
by on-site managers and network administrators. Administrator level accounts can use Web Maintenance
Console to add users or programme user settings.
User (Administrator) accounts are intended for maintenance functions only. To manage their own PBX
user settings, on-site managers and network administrators should create their own User (User) accounts
for programming.
•
User (User)
User accounts are for individual users of the PBX system. Users can use Web Maintenance Console to
change their extension settings, speed dial settings, or other personal settings by accessing a limited
number of pre-defined menus.
Note
•
User (User) accounts cannot be used when programming in Off-line mode. For details, refer to
1.2.2 PC Programming Using Off-line Mode
Account Login Names and Passwords
Each account has a login name and password and are specified as follows. All account passwords are set in
Web Maintenance Console (see
8.2.1 Users—Add User—Single User
32
PC Programming Manual
2.1.1 Web Maintenance Console Accounts
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...