9.12 PBX Configuration—[1-1]
Configuration—Slot—V-IPGW—Port Property
Various settings can be programmed for each virtual IP Gateway port.
The
Shelf
,
Slot
, and
Port
for each item are displayed for your reference. For details, see
9.1 PBX Configuration—[1-1] Configuration—Slot
.
Trunk Adaptor
To connect to a Trunk Adaptor, follow the steps below.
1.
Ensure that the Trunk Adaptor is connected to the network and a power supply.
2.
Click
Trunk Adaptor
. The
Trunk Adaptor List
screen is displayed.
3.
Enter a name (20 characters or less) for the Trunk Adaptor in
Trunk Adaptor Name
.
4.
Enter the Trunk Adaptor’s IP address in
Trunk Adaptor IP Address
.
5.
To confirm that the setting is correct, click
CONNECT
. If the setting is correct, the Trunk Adaptor’s Web
Maintenance Console will open in a new browser window.
For details about the Trunk Adaptor’s Web Maintenance Console, refer to the documentation of the Trunk
Adaptor.
6.
Click
OK
.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS
or
OUS
for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Connection Attribute
Specifies whether to connect a port to a Trunk Adaptor or use it as an IP gateway.
Value Range
Gateway, Trunk Adaptor
Feature Guide References
5.3.1 Trunk Adaptor Connection
Call Distribution Port Group
Specifies a call distribution port group to which incoming trunk calls are directed through the virtual VoIP
gateway port.
Value Range
1–48
PC Programming Manual
253
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW—Port Property
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...