9.8 PBX Configuration—[1-1]
Configuration—Slot—V-SIPGW—Shelf Property
Common settings for all of the V-SIPGW cards installed in the Virtual Shelf can be programmed.
Icon Description
In this section, the following icons show the different parameter type.
Icon
Description for Parameter Type
Manual programming is compulsory under certain conditions.
Manual programming is optional.
Main
SIP Client Port Number
Specifies the port number of the PBX used for communications with the SIP server.
Value Range
1024–65535
NAT Traversal
Specifies the NAT traversal method.
–
STUN: A STUN Server, used alongside the SIP Server, finds out the global IP address of the router with
NAT enabled.
–
Fixed IP Addr.: The global IP address of the router with NAT enabled is fixed.
Note
Manual programming is optional except when programming is required depending on the network
conditions.
Value Range
Off, Fixed IP Addr., STUN
NAT - Voice (RTP) UDP Port No.
Specifies the starting port number of the dynamic ports used for NAT Traversal.
Value Range
1024–65535
NAT - Keep Alive Packet Sending Ability
Specifies whether to send Keep Alive packets in order to maintain the NAT binding information. This setting
may be compulsory depending on the network conditions.
Value Range
Disable, Enable
PC Programming Manual
217
9.8 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Shelf Property
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...