7.1.6 Troubleshooting by Error Log
When a major system error occurs in the PBX, the STATUS indicator on the front of the cabinet turns red, and
the system logs the error information.
Error Log Display Format
Below is the display format of the error log. For information about how to view the error log using Web
Maintenance Console, refer to "7.3.1 Utility—Log—Error Log" in the PC Programming Manual.
Example: Web Maintenance Console
3
7
1
2
4
5
6
Example: Station Message Detail Recording (SMDR)
01/01/10 01:00AM MJ ALM #014 00 10000 FAN Alarm
01/01/10 01:29AM MN ALM #533 01 50401 Unit start up error
01/01/10 01:39AM MN ALM #091 00 10000 PT connection over
1
2
3
4
5
6
Description
Item
Description
1
Date
The date of the error detection.
2
Time
The time of the error detection.
3
Level
Minor (MN ALM)
Displays minor errors, which affect only a certain part of system
operation.
Major (MJ ALM)
Displays major errors, which affect operation of the whole
system, or result in system failure.
4
Error Code
The 3-digit error code assigned by the PBX. For details about
the error code, refer to item 7 in this table.
330
Installation Manual
7.1.6 Troubleshooting by Error Log
Summary of Contents for KX-NS1000
Page 40: ...40 Installation Manual 1 4 Data Security ...
Page 76: ...76 Installation Manual 2 3 3 System Capacity ...
Page 108: ...108 Installation Manual 3 1 3 Using CTI Applications ...
Page 267: ...the priority Installation Manual 267 5 8 3 Setting LLDP Parameters ...
Page 312: ...312 Installation Manual 5 12 Automatic Configuration of Mailboxes ...
Page 318: ...318 Installation Manual 6 2 Methods of Stacking PBXs ...
Page 332: ...332 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Page 400: ...400 Installation Manual 8 6 26 WAN Port Mirroring ...
Page 414: ...414 Installation Manual 9 3 7 PCMPR Software File Version 004 1xxxx ...