4.2.4 Frame Earth Connection
1.
Loosen the screw.
2.
Insert an earthing wire (user-supplied).
3.
Tighten the screw.
4.
Connect the earthing wire to earth.
Screw
Earthing wire
To earth
WARNING
•
Proper earthing (connection to earth) is very important to reduce the risk to the user of
electrocution or to protect the PBX from the bad effects of external noise in the case of a
lightning strike.
•
The earthing wire of the AC cable has an effect against external noise and lightning strikes, but
it may not be enough to protect the PBX and to ensure electromagnetic compatibility. A
permanent connection between earth and the earth terminal of the PBX must be made.
CAUTION
For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of the conductor
must be more than 0.75 mm
2
or 18 AWG.
Notice
Be sure to comply with applicable local regulations (e.g., laws, guidelines).
Installation Manual
117
4.2.4 Frame Earth Connection