background image

Installation Guide

Home Network System

Window/Door Sensor

Model No.    

KX-HNS101E

Thank you for purchasing a Panasonic product.

This document explains how to install the window/door sensor
properly.
For details about how to use the system, refer to the User’s Guide
(page 19).

Please read this document before using the unit and save it for future
reference.
For dedicated help, support, or advice, available to help you Monday -
Friday, 09:00 - 23:00. For U.K., please contact us on 0330 3331112 and
for Ireland 01 4475228.

HNS101E_(en_en)_0421_ver.060.pdf   1

2015/04/21   14:21:39

Summary of Contents for KX-HNS101E

Page 1: ...to install the window door sensor properly For details about how to use the system refer to the User s Guide page 19 Please read this document before using the unit and save it for future reference For dedicated help support or advice available to help you Monday Friday 09 00 23 00 For U K please contact us on 0330 3331112 and for Ireland 01 4475228 ...

Page 2: ...ames and functions 9 LED indicator 9 Setup overview 9 Inserting the battery 10 Registering the window door sensor 11 Changing the sensor type 11 Wireless communication range 12 Temporary placement 13 Installation 16 Appendix Testing the window door sensor 19 Features available when using the Home Network app 19 Accessing the User s Guide 19 Specifications 20 Conditions of guarantee 21 2 Table of C...

Page 3: ...these instructions may vary slightly from the actual product Trademarks R iPhone and iPad are trademarks of Apple Inc registered in the U S and other countries R Android is a trademark of Google Inc R Microsoft Windows and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries R All other trademarks identified herein ar...

Page 4: ...ribution facilities are provided directly by Panasonic U K General information R The objective hub for the following model is shown below KX HNS101E Hub KX HNB600E R Please read General information of the hub s system setup guide for information regarding R TTE Directive For your future reference We recommend keeping a record of the following information to assist with any repair under warranty Se...

Page 5: ...atic doors and fire alarms Radio waves emitted from this product may cause such devices to malfunction resulting in an accident R Keep small parts magnet unit magnet unit cover screws etc out of the reach of children There is a risk of swallowing In the event they are swallowed seek medical advice immediately Operating safeguards R Do not disassemble the product Medical R Consult the manufacturer ...

Page 6: ...ttempt to use a battery if it is leaking R Exercise care when handling the batteries Do not allow conductive materials such as rings bracelets or keys to touch the batteries otherwise a short circuit may cause the batteries and or the conductive material to overheat and cause burns Important safety instructions When using your product basic safety precautions should always be followed to reduce th...

Page 7: ...m the electrical appliances Other information CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Routine care R Wipe the outer surface of the product with a soft moist cloth R Do not use benzine thinner or any abrasive powder Disposal of Old Equipment and Batteries Only for European Union and countries with recycling system...

Page 8: ...with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Note for the battery removal procedure Refer to Inserting the battery on page 10 8 Helpline Tel No U K 0330 3331112 Ireland 01 4475228 Important Information ...

Page 9: ...nge of the hub Green blinking Registration mode You pressed and held M N Off No battery power Note R The LED indicator does not indicate sensor status if the sensor has not been registered page 11 Setup overview 1 Initial setup Make sure you can access the system using your mobile device For details refer to the System Setup Guide included with your hub 2 Insert the battery The window door sensor ...

Page 10: ...allation Install the window door sensor on the same position where proper operation was confirmed page 16 Inserting the battery R USE ONLY a CR2 Lithium battery R Confirm the polarities 1 Remove the sensor unit cover R Lift from the indented area A and open the sensor unit cover B 1 2 2 Insert the battery 3 Attach the sensor unit cover 10 Helpline Tel No U K 0330 3331112 Ireland 01 4475228 Setup ...

Page 11: ...it cover and press and hold M N until the LED indicator blinks in green page 9 R When registration is complete the hub sounds one long beep Note R To cancel without registering the sensor press M N on the hub and on the sensor again R If registration fails the hub sounds several short beeps Using the app When you register the window door sensor by using the Home Network app you can assign a name t...

Page 12: ... R Walls containing aluminium sheet insulation R Walls made of concrete or corrugated iron R Double pane glass windows R Multiple walls R When using each device on separate floors or in different buildings Note R You can check the window door sensor s communication status by pressing M N If the LED indicator is lit in green or red the sensor is communicating properly with the hub If the LED indica...

Page 13: ...the desired location press M N while the window or door is closed The window door sensor s LED indicator lights as follows Indicator Status Green lit The installation position is correct Red lit The marks on the sensor unit and the magnet unit are too far from each other Re attach the sensor unit and the magnet unit so that they point directly at each other and are no more than 25 4 mm apart Red b...

Page 14: ...ess M N A the LED indicator lights in green B Incorrect 2 3 4 A B Red 2 marks are aligned but units are too far apart 3 marks are aligned but window frame is too thick units are too far apart 4 marks are not aligned Magnet unit is too high Result When you press M N A the LED indicator lights in red B 14 Helpline Tel No U K 0330 3331112 Ireland 01 4475228 Setup ...

Page 15: ...ress M N A the LED indicator lights in green B Incorrect 2 3 4 A B Red 2 marks are aligned but units are too far apart 3 marks are aligned but window frame is too thick units are too far apart 4 marks are not aligned Magnet unit is too high Result When you press M N A the LED indicator lights in red B Helpline Tel No U K 0330 3331112 Ireland 01 4475228 15 Setup ...

Page 16: ...he material of the installation area Note R When installing make sure the battery is inserted properly and the sensor unit cover is completely closed R Use screws when installing on a wooden surface Do not use double sided tape Securing with screws 1 Remove the covers from each unit R Lift from the indented area A and open the sensor unit cover B 1 2 1 2 16 Helpline Tel No U K 0330 3331112 Ireland...

Page 17: ... the magnet unit 3 Screws 4 24 4 mm 2 4 1 1 3 3 5 3 Attach the covers Important R 5 Align the marks on the sensor unit and the magnet unit so that they point directly at each other and are no more than 25 4 mm apart Helpline Tel No U K 0330 3331112 Ireland 01 4475228 17 Setup ...

Page 18: ...k of each unit 5 3 Install the sensor unit and magnet unit R Press firmly on each unit to ensure solid adhesion to the installation surface Important R 5 Align the marks on the sensor unit and the magnet unit so that they point directly at each other and are no more than 25 4 mm apart Removing when secured with double sided tape 1 Tie a piece of thread to two sticks screwdrivers etc 2 Pull the thr...

Page 19: ...he alarm system confirm the current status of the sensor and view a log of previous events Sensor integration You can configure the window door sensor to trigger other system events such as camera recording turning on an electric device such as a lamp etc Appropriate device required Telephone alert You can configure the system to call a preprogrammed phone number when the window door sensor is tri...

Page 20: ...R Battery life Up to 2 years when window door is opened and closed 10 times a day in an environment of 25 C when using a 3 0 V 850 mAh battery The battery life differs depending on the capacity of the battery used R Dimensions height width depth Sensor unit Approx 102 mm 31 mm 22 mm Magnet unit Approx 37 mm 14 mm 14 mm R Mass weight Sensor unit Approx 39 g excluding the battery Magnet unit Approx ...

Page 21: ...ountry where this product is used or to damage occurred during transit to or from the purchaser 4 If at any time during the guarantee period any part or parts of the product are replaced with a part or parts not supplied or approved by us or of an objective quality safe and suitable for the product or the product has been dismantled or repaired by any person not authorised by us we shall have the ...

Page 22: ...22 Notes ...

Page 23: ...23 Notes ...

Page 24: ...erly If you still have any problems please call the Helpline 0330 3331112 U K 01 4475228 Ireland or contact us through our website www panasonic co uk Sales Department Panasonic House Willoughby Road Bracknell Berkshire RG12 8FP 1 62 4 chome Minoshima Hakata ku Fukuoka 812 8531 Japan Panasonic System Networks Co Ltd 2015 PNQX7280ZA PNQX7280ZA PNQX7280ZA CC0415WK0 E ...

Reviews: