ANNEX_G_STUN_MIN_KEEP_ALIVE
Value Format
INTEGER
Description
Specifies the minimum period, in seconds, that STUN Binding
Requests can be sent by the CPE for the purpose of maintaining the
binding in the Gateway. This limit applies only to Binding Requests
sent from the UDP Connection Request address and port, and only
those that do not contain the BINDING-CHANGE attribute.
Note
•
This setting is available only when "
ANNEX_G_STUN_ENABLE
"
is set to "
Y
".
Value Range
1–3600
Default Value
30
UDP_CON_REQ_ADDR_NOTIFY_LIMIT
Value Format
INTEGER
Description
Specifies the minimum time, in seconds, between Active Notifications
resulting from changes to the "UDPConnectionRequestAddress" (if
Active Notification is enabled).
Value Range
0–65535
Default Value
0
DEVICE_PROVISIONING_CODE
Value Format
STRING
Description
Specifies the device provisioning code for use with TR-106
parameters.
Value Range
Max. 64 characters
Default Value
Empty string
5.3.10 XML Settings
XMLAPP_ENABLE
Value Format
BOOLEAN
Description
Specifies whether to enable the XML application feature.
Value Range
•
Y
: Enable XML application
•
N
: Disable
Default Value
N
Web User Interface Reference
XMLAPP_USERID
Value Format
STRING
5.3.10 XML Settings
Document Version 2016-05
Administrator Guide
195
Summary of Contents for KX-HDV430
Page 8: ...Table of Contents 8 Administrator Guide Document Version 2016 05...
Page 148: ...4 7 5 Restart 148 Administrator Guide Document Version 2016 05...
Page 304: ...5 3 38 Logging Settings 304 Administrator Guide Document Version 2016 05...
Page 328: ...7 3 Executing Firmware Update 328 Administrator Guide Document Version 2016 05...
Page 333: ...Note Document Version 2016 05 Administrator Guide 333...
Page 334: ...Note 334 Administrator Guide Document Version 2016 05...
Page 335: ...Note Document Version 2016 05 Administrator Guide 335...