Description
Specifies the pattern, in milliseconds, of Dial Tone 1 using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range
0–16000 (msec) (0=Continuous)
Note
•
Avoid setting 1–50 for any of the values.
Default Value
60,0
Web User Interface Reference
DIAL_TONE2_FRQ
Value Format
Comma-separated Integer
Description
Specifies the dual-tone frequencies, in hertz, of Dial Tone 2 using 2
whole numbers separated by a comma.
Value Range
0, 200–2000 (0: No tone)
Default Value
350,440
DIAL_TONE2_GAIN
Value Format
INTEGER
Description
Specifies the gain, in decibels, of Dial Tone 2.
Value Range
-24–6 (dB)
Default Value
0
DIAL_TONE2_RPT
Value Format
INTEGER
Description
Specifies whether Dial Tone 2 is repeated.
Value Range
0–1
–
0: No Repeat
–
1: Repeat
Default Value
0
DIAL_TONE2_TIMING
Value Format
Comma-separated Integer
292
Administrator Guide
Document Version 2015-07