ADJUSTMENT
ADJUSTMENT:
LENS AND CCD READ POSITION ADJUSTMENT
1) Loosen the lens fixing screw and CCD board fixing screw.
2) Adjust the position of the lens and CCD board so that the waveform appears as shown in the figure below.
3) Fix the lens fixing screw and CCD board fixing screw.
Oscilloscope setting
CH1 ........... 0.5 V/div
CH2 ........... 2 V/div
TIME .......... 1 ms
Trigger ....... CH2
Mode ......... AC
CN7
CN6
FIG
AG
AMON
VID
(DIGITAL BORAD)
OSCILLOSCOPE
CH1
CH2
To point "FTG".
To point "VID".
Extension cord (Part No. PQZZ2K12Z)
To LED array for CCD Unit.
Extension Cord
(Part No. PQZZ8K18Z)
To CCD baord
"Never connect land "AMON"
Lens fixing screws
CCD board fixing screws
MAX
(for Lens)
MAX
(for CCD Board)
WAVEFORM