57
|
KX-F910BX
TROUBLESHOOTING GUIDE
Pleas check the status (voltage) of pin 56, pin 58 and pin 60 of IC1.
These status may tell you defective point. (Please use the ROM for IC status checked) [Ref No. EC22]
This could be
defective point
Please check here!
AC
status (voltage) of check points
TESTER
Oscilloscope
or
IC1 (ASIC)
pin 58
pin 56
pin 60
0v
0v
5v
5v
0v
5v
0v
5v
0v
0v
0v
0v
SRAM
IC3
MODEM
IC11
OPE.PANEL
IC301
IC3,IC1 (pin 48)
IC11 (pin 95, pin 116),RA1,RA2
Change the Cordless Base unit P.C.B.
IC1 (pin 14~17, pin 20)
R79~R86
0v
5v
5v
Thermal Head
TEMP.
R47~R49, C37~C39
IC1 ( pin 38, pin 49)
Note: If the thermal head temperature is
abnormal, "CALL SERVICE" will appear in
the dispaly.
Please check soldering and conduction of these components.
If it is no problem, replace ICs.
If you still have problem, please go to "3-1 check detail" (page 58).
ALL OK
5v
0v
0v
Cordless
GND
Summary of Contents for KX-F910BX
Page 1: ......
Page 176: ......
Page 177: ......
Page 178: ......
Page 179: ......
Page 180: ......
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 195: ......
Page 196: ......
Page 197: ......
Page 198: ......
Page 199: ......
Page 200: ......
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 209: ......
Page 217: ......