Items
Adjustment
Point
Procedure
Check
Replac
Parts
(O)
*
Receive Audio
Check and
Confirmation
TP15
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: PP
-Mode: Nomal
-RFPI: 0102030405
2. Execute the command "testmode".
3. Execute the command "regcmd60"
4. Initiate connection from DECT tester.
5. Execute the command "openaudio".
6. Confirm that the value of EEPROM address "F3F" is "02". (If the value is not "02 (by
User)", set "02" and power off and power on, and return to clause 2.)
7. Input audio signal (50mVrms/1kHz tone) from DECT tester.
<DECT tester setting>
-Scramble: On
-AF Gen to ADPCM: On
-AF Meter Input: AF Voltm
-AF Gen Frequency: 1000Hz
-AF Gen Level: 50mVrms
8. Confirm hearing tone: 300mV ± 250mV (Just check Audio path)
9. Confirm that the audio distortion with DECT tester is < 5 %.
IC1, C1
C31,
R17, R
C10,
C11, D
D6,
IC3, C5
C66,
C60, L
C57,
C55, C
C62,
R23, R
C63,
C64, C
R18
(P) Transmit Audio
Check and
Confirmation
TP15
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: FP
-Mode: Normal
-RFPI: 0102030405
2. Execute the command "testmode".
3. Execute the command "regcmd60".
4. Initiate connection from DECT tester.
5. Execute the command "openaudio".
6. Confirm that the value of EEPROM address "F3F" is "02". (If the value is not "02 (by
User)", set "02" and power off and power on, and return to clause 2.)
7. Input audio signal (30mVrms/1kHz tone) to DECT tester.
<DECT tester setting>
-Scramble: On
-AF Gen to ADPCM: Off
-AF Meter Input: ADPCM
-AF Gen Frequency: 1000Hz
-AF Gen Level: 30mVrms
8. Confirm hearing tone: 300mV ± 250mV (Just check Audio path)
9. Confirm that the audio distortion with DECT tester is < 5 %.
IC1, C
R7,
R8, C6,
C5, R5,
C4, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
Note:
After the measuring, sock up the solder of TP.
* :
PC Setting
() is required beforehand.
The connection of adjustment equipment are as shown in
Adjustment Standard (Handset)
().
15.2. Adjustment Standard (Handset)
When connecting the Simulator Equipments for checking, please refer to below.
Note:
49
www.freeservicemanuals.info
11/8/2014
Digitized in Heiloo, Holland
Summary of Contents for KX-A141AXM
Page 51: ...18 FREQUENCY TABLE MHz 51 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Page 74: ...74 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Page 76: ...76 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Page 82: ...82 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...