Items
Adjustment
Point
Procedure
Check
Replac
Parts
(K
)
Frequency
Offset
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Confirm that the frequency offset is < ± 50kHz.
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
(L)
Sensitivity
Receiver
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Confirm that the BER is < 1000ppm.
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
(M
)
Timing
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Confirm that the Timing accuracy is < ± 10ppm.
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
(N
)*
RSSI Level
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Execute the command "readrssi"
7. Confirm that the returned value is 0x34 ± A (hex).
IC1, IC
C54,
C66, C
L3,
C57, C
C56,
C62, R
R24,
C63, C
C65,
R18
48