4. Type “doskey”.
Note:
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data
from address “00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is
read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the
ID “0018 E0 0E 98” is written.
setfreq
adjust Frequency of RFIC
Type “setfreq nn nn”.
hookoff
off-hook mode on Base
Type “hookoff”.
hookon
on-hook mode on Base
Type “hookon”.
Getchk
Read checksum
Type “getchk”.
Wreeprom
write eeprom
Type "wreeprom 01 23 45". "01 23" is
address and "45" is data to be written.
InitBsPIN.bat
Initial Base PIN to "0000"
Type "initBsPIN"
13. CHECK PROCEDURE (HANDSET)
13.1. Preparation
13.1.1. Equipment Required
- DECT tester: Rohde & Schwarz, CMD 60 is recommended.
- Frequency counter: it must be precise to be able to measure 1Hz
(precision;±4ppm).
Hewlett Packard, 53131A is recommended.
- DC power: it must be able to output at least 1A current under 2.4V for
Handset, 9V for JIG.
- Digital multi-meter (DMM): it must be able to measure voltage and
current.
- Oscilloscope
13.1.2. JIGs and PC
- EEPROM serial JIGs
1. I2C PCB: PQZZTCD705BX
2. RS232C cable: PQZZ1CD705BX
3. Clip cable: PQZZ2CD705BX
4. DC cable: PQZZ3CD705BX
- PC which runs in DOS mode.
- Batch file for PC setting: PQZZTCD410AX
35
www.freeservicemanuals.info
11/8/2014
Digitized in Heiloo, Holland
Summary of Contents for KX-A141AXM
Page 51: ...18 FREQUENCY TABLE MHz 51 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Page 74: ...74 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Page 76: ...76 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...
Page 82: ...82 www freeservicemanuals info 11 8 2014 Digitized in Heiloo Holland ...