5.4 Specifications — KX-TDA30
Installation Manual
243
5.4
Specifications — KX-TDA30
5.4.1
General Description
Switching
Non-blocking
AC Adaptor
AC Input
100 V AC to 240 V AC, 1.5 A, 50 Hz/60 Hz
DC Output
40 V, 1.38 A (55.2 W)
DC Input
•
DC IN 1: 40 V, 1.38 A (55.2 W)
•
DC IN 2: 40 V, 1.38 A (55.2 W)
External Battery
+36 V DC (+12 V DC
×
3, battery capacity of 14 Ah or below
recommended for each external battery)
Maximum Power Failure
Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Connectors
Trunk
RJ45/RJ11 (2 wire)
×
each trunk port
Extension
RJ45/RJ11 (4 wire)
×
each extension port
Paging Output
1 conductor jack
External MOH
(Music on Hold)
Output
1 conductor jack
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
Conference Call Trunk
From 10
×
3-party conference call to 4
×
8-party conference call
Music on Hold
1 port (Level Control: -11 dB to +11 dB in 1 dB steps)
Selectable Tone/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
1 port (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface
Port
RS-232C
1 (maximum 115.2 kbps)
USB
1
Summary of Contents for HYBRID IP-PBX KX-TDA100
Page 20: ...20 Installation Manual ...
Page 248: ...5 4 Specifications KX TDA30 248 Installation Manual ...
Page 390: ...6 12 Starting the Hybrid IP PBX KX TDA30 390 Installation Manual ...
Page 420: ...8 1 Troubleshooting KX TDA30 420 Installation Manual ...
Page 421: ...Installation Manual 421 Index ...
Page 426: ...Index 426 Installation Manual ...