background image

INSTRUCTION MANUAL

Ultra High-Speed, High-Accuracy Laser Displacement Sensor

Sensor Head

HL-C235CE-W□

MJE-HLC235EW(02) No.0048-80V

Thank you very much for purchasing Panasonic products. Read this Instruction Man-

ual carefully and thoroughly for the correct and optimum use of this product. Kindly 

keep this manual in a convenient place for quick reference.

WARNING

 

 This product is intended to detect the objects and does not have the control func-

tion to ensure safety such as accident prevention.

Do not use the product as a sensing device to protect human body.

 

●  Be careful not to directly watch or touch the direct laser beam or reflected laser 

beam.

 

The product was developed and manufactured for industrial use.

BEFORE USE

 

Before using the product, check the sensor head model and contents of packing.

 

 Sensor head model

Check the model name of product at the top of sensor head.

 

 Packing

Check that all of the following components are included in the 

package.

• 

1 sensor head unit

• 

1 Instruction manual

• 

Laser warning labels

[JIS/IEC: 1 set, GB: 1 set (E type only)]

 

●  This product satisfies the adaption of CE product by using in combination with 

controller and programmable display, which are subjected to CE. Please confirm 

that there is CE mark on connecting controller’s label.

 

Contact for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center

Winsbergring 15, 22525 Hamburg,Germany

1

DESCRIPTION

 

 

HL-C235BE-W□

HL-C235CE-W□

 displacement sensor head achieves ultra high-

speed and high-accurate measurement using linear image sensor as light receiv-

ing element to be used on equipment that require high-speed operation with high-

accuracy.

2

CAUTIONS ON HANDLING LASER LIGHT

 

 For the purpose of preventing any injury which may occur to the user by the use 

of the laser product in advance, the following standards have been established by 

the IEC Standards, JIS Standards, GB Standards and FDA Standards.
IEC  :   IEC 60825-1

-2007

JIS  :   JIS C 6802

-2011

GB  :   GB 7247.1

-2012

FDA :   PART 1040.10

These standards classifies laser products according to the level of hazard and 

provide the safety measures for respective classes.

 

 Laser hazardous class

Classification according to IEC 60825-1

-2007 

(JIS C 6802

-2005

)

Class

Model

Description of hazardous evaluation

Class 3R

HL-C235CE-W

HL-C235CE-WMK

Direct intrabeam viewing is hazardous, but risk is lower than for 3B.

 

 WARNING  label

<HL-C235CE-W□>

In Chinese

In Japanese / English / Korean

(E type only)

 

 FDA certification label

<Label position>

 

 Install the product so the laser beam comes higher or lower than eye level in order 

not to watch the beam directly during operation. Laser safety distance (Nominal 

Ocular Hazard Distance: NOHD) is approx. 1.4m. The laser beam must be termi

-

nated at the end of its path by a diffuse reflector or an absorber.

 

 Please contact our company if the system breaks down. It is not equipped with a 

function that stops laser radiation automatically during disassembling the sensor 

head. The users therefore may be exposed to laser beam in disassembling the 

sensor head.

 

●  When this product is used in China, affix the Chinese warning label (accessory) 

on the label in the product.

 

 

Do not use the system in the manner other than specified in this Instruction Manual.

3

SPECIFICATIONS

Model No.

HL-C235CE-W

HL-C235CE-WMK

Meas. method (Note 2)

Diffuse reflection

Measurement center distance

350mm

350mm

Measurement range (Note 3)

±200mm

±200mm

Beam source

Red semiconductor laser Class 3R (JIS/IEC/GB), Class IIIa (FDA) (Note 4)

Max output: 5mW, Emission Peak wavelength: 658nm

Beam diameter (Note 5)

Approx. 

ø

400μm

Approx. 400 × 6,500μm

Beam receiving element

Linear image sensor

Resolution

8μm / average times: 256, 2μm /average times: 4,096

Linearity

±0.04%F.S. (-200 to 0mm), ±0.08%F.S. (0 to +200mm) (F.S. = ±200mm)

Temperature characteristics

0.01%F.S./°C

Indicator

Laser emission

Green LED: Lights up during laser emission.

Meas. range

Yellow LED: Near measurement center:ON, within measurement range:Blink, beyond the range:OFF

Protective structure

IP67 (except connector)

Pollution degree

2

Insulation resistance

20M ohms or more by 500V DC megger (between all the terminals and enclosure.)

Dielectric withstand

Commercial Frequency

AC 500V for 1min. (between all the terminals and enclosure.)

Impulse

±1,000V 1.2/50μs (between all the terminals and enclosure.)

Vibration resistance

Endurance: 10 to 55Hz (cycle: 1minute), Resistant amplitude of vibration: 1.5mm, in 

X, Y, and Z directions for 2 hours

Shock resistance

196m/ s

2

 in X, Y, and Z directions for 3 times

Ambient illuminance (Note 6)

3,000ℓx or less (illuinance at beam receiving surface using incandescent lamp)

Ambient temperature

0 to +45°C (No dew condensation or icing allowed), At storage: -20 to +70°C

Ambient humidity

35 to 85%RH At storage:35 to 85%RH

Ambient Height

2,000m or less

Material

Main unit case / cover faluminum: Die-cast, Front cover: Glass

Cable length

0.5m

Cable extension

Extendible to 30m long maximum using the optional extension cable.

Weight

Approx. 300g including cable weight

Applicable standards

Conformed to EMC Directive

Notes: 1) Measuring conditions are as follows unless otherwise specified; connection with controller, power voltage: 

24V DC, ambient temperature: 20°C, sampling cycle: 40μs, average times:256, at measurement center dis

-

tance, object substance: white ceramic,, and digital measurement value.

 

2) Use the external ND filter (optional) in case the amount of reflected beam is too large on Specular Reflection 

installation.

 

3) The measurement range is limites between -70 and +200mm (in case the sampling cycle is 20μs), or be

-

tween +100 and +200mm (in case the sampling cycle is 10μs).

 

4) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard.

 

5) The figure shows the value at measurement center distance. It is determined by 1/e

2

 (approximately 13.5%) 

of center beam intensity. Due to leak light outside the specified area, the reflectance around the detecting 

point may be higher than at the point and this may affect the measurement value.

 

6) The variation in ambient illuminance is ±0.08%F.S. or less.

4

EXPORT REGULATIONS BY JAPANESE GOVERNMENT

 

●  Please follow the export control regulations required.

HL-C235CE-W

(

MK

) (E type) are not subject to export control regulations under 

the condition that they are used combined with the non-pertinent controller to ex

-

port control specified by Foreign Exchange and Foreign Trade Law.

When they are combined with the pertinent controller to export control, they are 

subject to the Law. In this case export admission by Japanese government is re

-

quired before the product is to be exported or brought out of the country.