Panasonic HG-S Series Instruction Manual Download Page 1

INSTRUCTION MANUAL

Contact-Type Digital Displacement Sensor / Sensor Head

HG-S□

MJE-HGS1010 No.0052-70V

Thank you very much for purchasing Panasonic products. Read this Instruction Man-

ual carefully and thoroughly for the correct and optimum use of this product. Kindly 

keep this manual in a convenient place for quick reference.

WARNING

 

Never use this product as a device for personnel protection.

 

When using devices for personnel protection, use products that meet the laws 

and standards for personnel protection that apply in each region or country, such 

as OSHA, ANSI and IEC.

This document provides a brief summary of mounting and other related information.

For detailed information, refer “

our web site (http://panasonic.net/id/pidsx/global)

”.

1

STANDARDS AND REGULATIONS

 

This product conforms to the standards and regulations below.

<European Directives>

EMC Directive

 

Contact for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center

Winsbergring 15, 22525 Hamburg,Germany

2

CONTENTS OF PACKAGE

 Sensor head 

1 pc.

 Mounting nut 

1 pc.

 Sensor head fastening wrench 

1 pc.

 Rubber bellows (

HG-S□R

 only) 

1 pc.

 Instruction Manual (English / Japanese, Chinese / Korean) 

2 pcs.

3

DESCRIPTION OF PARTS

Rubber bellows

Operation indicator (Orenge / Green)
Mounting nut

Sensor head connection cable connector

Probe

4

MOUNTING

 

When tightening the mounting nut, take care not to damage the rubber bellows.

 

If the rubber bellows is deformed, a load will occur when the spindle operates 

and damage may result.

1. 

 Open a hole in the housing in which the sen-

sor head will be mounted.

6.5 to 12.5mm

Mounting hole 

ø8H7 

+0.015

0

 mm

2. 

 Insert the sensor head into the hole you 

opened in the housing, and fasten lightly 

with the provided mounting nut.

Mounting nut

(Accessory)

3. 

 Fasten the sensor head.

When fastening the sensor head, tighten the 

mounting nut with a wrench while holding the 

sensor head in place with the sensor head 

fastening wrench as shown at right.

Tighten to a torque of 12.5N·m or less.

Sensor head 

fastening wrench 

(Accessory)

Wrench

4. 

 Make sure that the rubber bellows has not 

become deformed as shown at right.

If the rubber bellows is deformed, restore the 

normal shape by rotating the bellows or oth-

erwise.

Connecting the sensor head connection cable

When disconnecting, always make sure that the fastening ring has been complete-

ly loosened before pulling out the cable.

Risk of damage if you pull the cable with excessive force (15N or more) with the 

fastening ring tightened.

How to connect

1. 

 Insert the sensor head connection 

cable into the connector for the 

sensor head connection cable on 

the sensor head.

2. 

 Turn the fastening ring on the sen-

sor head connector in the direction 

shown to fasten the ring.

1.

 Insert

2.

 Tighten

How to remove

1. 

 Turn the fastening ring on the sen-

sor head connector in the direction 

shown to loosen the ring.

2. 

 Grasp the connector and pull up to 

remove the cable.

2.

 Pull out

1.

 Loosen

Reviews: