20
Indication contents
• Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
• The error cord contents which are displayed
Touch the [BAK] of LCD to end the service mode, and then POWER OFF.
6.3.
Power ON Self Check Result Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
• Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
-CAM-PWR : Communication test between IC3401 to IC2304
-CAM-UNI : IC3401 internal communication test.
Display other than "OK" are abnormalities of each lines.
Cutting of battery connection or AC power supply connection to end the service mode.
Error
code Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal
Summary of Contents for HC-X900EB
Page 10: ...10 3 5 Formatting ...
Page 11: ...11 4 Specifications ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 15: ...15 5 Location of Controls and Components ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 30: ...30 8 3 5 Removal of the Top OP Unit Fig D6 Fig D7 ...
Page 33: ...33 Fig D13 8 3 11 Removal of the Flash P C B Fig D14 ...
Page 37: ...37 8 3 18 Removal of the Barrier Case Unit Fig D25 Fig D26 ...
Page 39: ...39 Fig D30 Fig D31 Fig D32 ...
Page 40: ...40 8 3 21 Removal of the EVF Lens Holder Unit Fig D33 Fig D34 ...
Page 44: ...44 8 3 29 Removal of the MOS Unit Fig D44 8 3 30 Removal of the Stepping Motor Fig D45 ...