Chapter 3 Preparation
—
Setting of time data
- 46 -
∫
Setting range of time code
The range of the time code that can be set differs depending on the frame rate of [REC FORMAT].
@
NOTE
0
The set change is not reflected if the time code setting screen is closed without confirming the setting value.
0
Set the number of frames with a value that is a multiple of 4 when the frame rate of [REC FORMAT] is set to 23.98p. The recorded time code will shift
with any other value.
0
In the following cases, [DF/NDF] is fixed to [NDF]:
j
When the frame rate of the [REC FORMAT] is 23.98p
j
When interval recording is enabled
Time code function during battery replacement
The operation of the time code generator will continue by the backup mechanism functioning even when replacing the battery.
The time code of the free run may shift when any item in the [SYSTEM] menu
→
[FREQUENCY], [FILE FORMAT], or [REC FORMAT] is changed.
After turning on the power again with the power button, check the time code and set again if necessary.
Time code in super slow recording
The time code is fixed to [REC RUN] when the super slow recording function is enabled.
≥
The time code output from the <SDI OUT> terminal
*
or the <HDMI> terminal proceeds at 1
×
speed starting at the same time as recording.
* Available for use when using
[FREQUENCY]
Frame rate of [REC FORMAT]
Range of the time code that can be set
[59.94Hz]
59.94p, 29.97p, 59.94i
00:00:00:00 to 23:59:59:29
23.98p
00:00:00:00 to 23:59:59:23
[50.00Hz]
50.00p, 25.00p, 50.00i
00:00:00:00 to 23:59:59:24
X2000