background image

INSTRUCTIONS

Cylindrical Inductive Proximity Sensor

GX-M

 

Series

Thank you for purchasing products from Panasonic. Please read this 

Instruction Manual carefully and thoroughly for the correct and optimum 

use of this product. Kindly keep this manual in a convenient place for quick 

reference.

WARNING

 

Never use this product as a sensing device for personnel protection.

 

In case of using sensing devices for personnel protection, use 

products which meet laws and standards, such as OSHA, ANSI 

or IEC etc., for personnel protection applicable in each region or 

country.

1

Cautions

 

This product has been developed / produced for industrial use only.

 

Make sure that the power supply is off while wiring.

 

If the power is supplied from a commercial switching regulator, ensure 

that the frame ground (F.G.) terminal of the power supply is connected 

to an actual ground.

 

Ensure that an isolation transformer is utilized for the DC power 

supply. If an autotransformer is utilized, the main body or power supply 

may be damaged.

 

If the used power supply generates a surge, connect a surge absorber 

to the power supply to absorb the surge.

 

Short-circuiting the load or wrong wiring may burn or damage the 

product.

 

Do not run the wires together with high-voltage lines or power lines 

or put them in the same raceway. This can cause malfunction due to 

induction.

 

● Avoid using the product where there are strong magnetic fields as they 

may prevent the product from working according to the specification.

 

Verify that the supply voltage including the ripple is within the rating.

 

In case noise generating equipment (switching regulator, inverter 

motor, etc.) is used in the vicinity of this product, connect the frame 

ground (F.G.) terminal of the equipment to an actual ground.

 

Do not apply stress directly to the sensor cable joint by forcibly 

bending or pulling.

 

Do not use the product in dusty or dirty places or in places that are 

exposed to steam.

 

Protect the sensor from water, oil, grease, organic solvents such as 

thinner, etc., strong acid, and alkaline.

 

● This product cannot be used in an environment containing inflammable 

or explosive gasses.

 

Never disassemble or modify the product.

 

Make the cable length as short as possible to avoid noise.

2

Compliance with standards and directives

This product complies with the following standards and 

regulations.

For the EU: EMC Directive 2004/108/EC

 

For the US and Canada:  

ANSI/UL60947-5-2, CAN/CSA C22.2 No.14

 

For Korea: S1-G-1-2009, S2-W-5-2009

In case you require a UL listing mark or C-UL 

listing mark, use a class 2 power supply unit.

RoHS directive

 

This equipment complies with RoHS (CE and Chinese 

directive).

3

Sensor types

The GX-M series consists of 2- and 3-wire types. Both are available as 

cable type or connector type (M12) and can be connected correspondingly 

via cable or connector. Furthermore you may have purchased a shielded or 

non-shielded model.

Shielded cable type

Non-shielded cable type

The tip of the sensor is com-

pletely covered with a protective 

metal.

The tip of the sensor is not cov-

ered with a protective metal.

M12 connector type

The connector type is also 

available as shielded or non-

shielded type

4

Part description

GX_M□

2

3

3

1 4

1

Main body

2

Tip of the sensor

3

Nut

4

LED

5

Mounting

The values for the tightening torque of the different sensors and their con-

nectors are given in the table below. 

Model no.

Tightening torque

GX-M

M8

5 Nm

2 Nm

M12

6 Nm

2 Nm

M18

15 Nm

2 Nm

M30

40 Nm

2 Nm

The connector type is indicated with -Z.

1

Reviews: