Panasonic FV-15NLFS1 Installation And Operating Instructions Manual Download Page 9

Insert power cord plug into 

power socket, then open 

the control box cover and turn 

on the main switch. (Fig.12) 

Control panel

Air volume dial switch

Main switch

Port receptacle for add-on Module provides additional 

features. (Module sold separately) 

For details, please consult Panasonic Call Center 

Telephone : 1-866-292-7299 (USA)

                    

 

1-800-669-5165 (Canada)

”I” is on 

“O” is off

Control box cover

Filter indicator

Running indicator

Filter reset button

Default setting : 80 CFM

9

OPERATION

Humidity dial switch

Default setting : 80 %RH

If the product inside humidity detected by sensor is over than setting value, the fan will 

stop for 60 minutes, then according to the detected value to determine whether to 

operate.

If the switch is turned to OFF position, the humidity sensor detection function will be 

disabled.

Press the button after filter maintenance for resetting accumulated running time and the 

filter indicator will light off, the buzzer will turn off.

Adjusting the product air volume by this dial switch, you can choose 50, 60, 70, 

80, 90, 100, 110, 130, 150 CFM.

Adjusting the humidity protection value of the product by this dial switch, you can choose 

from 30 %RH~80 %RH (stepless) or turned to OFF position.

When the indicator is on green, indicates the product is running.

The indicator will light on red when the accumulated running 

time is up to 90 days. When the indicator is on (with buzzer 

sound), indicates need to maintain filters.

(1)The indicator will be on when the product accumulated 

     running time reaches to 90 days. The buzzer will sound 

     every hour and 10 seconds in an hour.

(2)If you want to turn off the indication of buzzer, please 

     press filter reset button about 3 seconds until there is the 

     sound of a long beep. Press filter reset button about 3 

     seconds again until there is sound of two quick beeps, the 

     buzzer indication will be turned on again.

(3)If you want to cancel buzzer sound when sleeping, you 

     just need to turn off the wall switch. The buzzer will 

    continue to sound when the product is turned back on and 

    will not stop until the filter has been maintained and the 

    filter alarm has been reset.

(4)When the the running indicator or filter indicator blinks, means 

    the product failure.

Note

Fig.12

1

1

2

2

4

3

5

4

6

5

3

I

O

Summary of Contents for FV-15NLFS1

Page 1: ...t Please read these instructions carefully before attempting to install operate or service the Panasonic product Please carefully read the GENERAL SAFETY INFORMATION P 2 4 of this manual before use Failure to comply with instructions could result in personal injury or property damage Please explain to users how to operate and maintain the product after installation and this booklet should be prese...

Page 2: ...ng the equipment with the grounding terminal For Your Safety Explanation of symbol word panels To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions The following symbols are used to classify and describe the type of instructions to be observed The following symbol word panels are used to classi...

Page 3: ...A Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA Always disconnect the power source before working on or near the fan or motor Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufact...

Page 4: ...nd close to duct adaptor GENERAL SAFETY INFORMATION NOTICE This product uses a sirocco fan driven by a DC motor powered by an integral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The blower uses a high capacity sirocco fan developed to reduce the noise level Unpack and remove product carefully from carton Refer to the s...

Page 5: ...IED ACCESSORIES DIMENSIONS 15 3 4 399 8 3 4 223 23 3 8 594 11 282 Φ 5 7 8 148 3 3 4 97 Φ 5 7 8 148 4 3 8 112 4 3 8 112 4 5 8 119 3 4 5 1 2 9 10 8 7 6 Part name No Part name No Main PCB Maintenance board Adaptor Pre filter Air flow Sub efficient filter Damper Motor Power cord Sirocco fan Control box cover 1 2 3 4 5 6 7 8 9 10 3 3 4 97 ...

Page 6: ...nut and washer should be M8 M10 and no provided Fig 4 3 Install the product on hanger bolts and fix the nuts tightly Fig 5 Please use the spirit level to adjust the body to ensure that the height of the three hangers within 2 mm Not applicable for ceiling with joists 3 Hanger bolts Hanger Maintenance board towards down Maintenance board Maintenance board Hanger Fix by 4 screws Hanger Fix by 3 scre...

Page 7: ...t the circular duct suggest using the insulated flexible duct to adaptor by mastic or approved foil tape Hanger Install the exterior duct with a declining slope toward outer side at least 1 100 Install the interior duct with a declining slope toward inner side at least 1 100 Fig 6 Note Fiberglass insulation Fig 7 17 3 4 450 1 5 8 40 1 1 4 30 17 3 4 450 Exterior duct Interior duct Mastic or approve...

Page 8: ...2 Install hanger bolts on ceiling and put washers and nuts on bolts Hanger bolt nut and washer should be M8 M10 and no provided Fig 9 3 Install the product on hanger bolts and fix the nuts tightly Fig 10 4 Install the ducts It is same with step 4 in P 7 5 Set an square inspection hole of 450 mm or more beside and below the maintenance board Fig 11 Please use the spirit level to adjust the body to ...

Page 9: ... 50 60 70 80 90 100 110 130 150 CFM Adjusting the humidity protection value of the product by this dial switch you can choose from 30 RH 80 RH stepless or turned to OFF position When the indicator is on green indicates the product is running The indicator will light on red when the accumulated running time is up to 90 days When the indicator is on with buzzer sound indicates need to maintain filte...

Page 10: ...AINTENANCE 10 OPERATION To avoid injury or electric shock turn off the main switch in control box to stop the fan before checking cleaning or replacing filter To ensure product running normally routine maintenance must be performed every 3 months Please wear gloves to avoid pinching fingers during maintenance When cleaning or replacing filters dust insects etc attached on the filters may fall Plea...

Page 11: ...sing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors and our fluorescent lamps do not create enough ambient heat to be subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the ...

Page 12: ...Center at 1 866 292 7299 USA or 1 800 669 5165 Canada P0118 0 15NLF4051 Printed in China Two Riverfront Plaza Newark NJ 07102 www panasonic com 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic com Panasonic Corporation 2018 Issue date 01 2018 PRODUCT SERVICE Air direction Voltage V Frequency Hz Duct inch Supply Speed rpm Weight Ib kg Static pressure Air volume CFM Power consumption W 6 ...

Reviews: