6. Finish ceiling work. Ceiling hole should be
aligned with the inside edge of the flange.
(Fig.4)
9. Install the night lamp and fluorescent lamps.
(Fig.6)
7. Remove the tape from mounting springs,
lead wire, and night lamp before
installation as shown below.
Fig.9
7
Before turn on the light, make sure the
conector insert at the correct position.
If not, the lighting can’t work.(Fig.8)
The claw of connector must latch the rib
completely.(Fig.8)
Mount grille carefully so that lead wire
of lighting unit is not pinched.
11. Insert the grille mounting spring which is
on the wiring
side into the slot. Then Insert
the plug connector into the housing of the
Junction box. (The lead wire should be fixed
by the four claws in the grille). Insert the
other mounting spring into the slot as shown
and mount grille to fan body. (Fig.8, Fig.9)
Fig.4
CAUTION
Fig.5
Fig.6
Fig.7
10. Reinstall the light cover.(Fig.7)
CAUTION
Lead wire
Night lamp
Tape
After finishing the ceiling job, fill gap between
flange and ceiling with caulk or other sealant to
prevent air leakage.
Tape
8. Remove the screw as shown in step 1 of Fig.5.
Remove the light cover as shown in step 2 of
Fig.5.
Summary of Contents for FV-08VSL3
Page 12: ...T0513 0 08VSL3420 2013 ...