Summary of Contents for FV-08VQS

Page 1: ...entilating Fan Failure to comply with instructions could result in personal injury and or property damage Please retain this booklet for future reference Table of Contents Unpacking 2 Supplied Accessories 2 Description 2 General Safety Information 3 Dimensions 4 Wiring Diagram 4 Installation I Joist Mounting I 5 6 Installation II Suspension Brackets Mounting 7 8 Installation III Joist Mounting II ...

Page 2: ...pension 1 bracket N Warranty 0 sheet DESCRIPTION These Panasonic ventilating fan models are listed by UL under UL file No E78414 These Panasonic ventilating fan models use a sirocco fan driven by a capacitor motor The motor is designed to have an extended service life with reduced energy consumption Quantity 2 1 6 2 1 It also incorporates a thermal cutoff for safety The grille covering the fan bod...

Page 3: ...cing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes a...

Page 4: ...t name 1 Blade 5 Fan body 2 Grille 6 Dam__l er 3 Junction box 7 Suspension bracket 4 Adaptor 8 Bracket cover WIRING DIAGRAM capacitor r W h lm M W h lm Black Black Black e Powar Supply ____ i 3 _ ti t AC120V 60Hz Fuse in motor Green Ear J i fD nd _ _ Fuse type e FV 5VQ5 237 F 114 c Earth ground Junction box FV 8VQ5 237 F 114 C FV 11VQ5 237 F 114 C FV 1 5VQ5 273 F 134 C __J Fan body 4 ...

Page 5: ...t I and n into the fan body Select the suspension bracket connection holes as shown below Fig 1 Suspension bracket connect method Suspension bracket I and II connect with screw I as shown below Unit inches mm 13114 151 2 336 394 16112 18 3 4 419 480 21 1 4 23 1 2 540 597 3 Install the suspension bracket and the flange of fan body to joists by using long screws 5T4 2X20 and secure it to the fan bod...

Page 6: ... Black Black Ul Black LI JV entJ Supp O AC12 Fuse in motor u Green Earth i round 60Hz Fuse type 1 I FV IlSVQS 237 F 114 C Earth ground Junction box FV IlBVQS 237 F 114 C I FV 1 1VQS 237 F 114 C I FV 15VQS 273 F 134 C I I I Fan body 7 Finish ceiling work Ceiling hole should be aligned with the inside edges of the flange Fig S IMPORTANT Remove the tapes from louver and springs before installation As...

Page 7: ...ethod Suspension bracket I and II connect with screwI as shown below Unit inches mm Suspension 131 4 15112 336 394 16 112 18 3 4 419 480 21 114 23 112 540 597 bracketII _ 3 Install the suspension bracket to joists by using long screws ST4 2X20 Fig 8 and secure it to the fan body by using screw n ST4 2X14 Fig 9 7 Fan body Suspension bracket Il Suspension bracket III 16 inches 406 mm or 19 inches 48...

Page 8: ...w 2 Secure 4 long screws ST 4 2X20 at flange of frame Fig 10 3 Follow steps 4 to 8 of installation I page 6 to complete the installation work MAINTENANCE CLEANING WARNING Disconnect power source before working on unit Routine maintenance must be done every year CAUTION 1 Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan 2 Do not immerse motor in water ...

Page 9: ...nic fans and fan light combination units do not create excessive heat that is Four inch or six inch roof jack wall cap or soffit vent with backdraft damper Mechanically connect duct to termination and seal with ma 1 ic or approved foil faced tape 2 3ft straight run before el lbowF iti In attic installation caulk box to drywall Short piece of flexible duct helps alignment and absorbs sound Clamps p...

Page 10: ...960 110 FV 15VQ5 Exhaust 120 60 6 0 3 28 5 700 150 HVI Certified performance based on HVI Procedures 915 916 and 920 PRODUCT SERVICE Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7292 USA or 1...

Page 11: ......

Page 12: ... Corporation of North America One Panasonic Way Secaucus New Jersey 07094 www panasonic com Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic ca A1002 0 08VQ54020 Printed in China ...