Table of Contents

List of components
Description
Dimensions
Specifications
Unpacking
General safety Information
Installation 

I

 (Joist mounting Installation)

Installation 

II

 (Wooden header Installation)

Installation 

III

 (Between joist mounting Installation)

Installation 

IV

 (ln existing construction)

Maintenance 

I (

Replacement of fluorescent lamp or night lamp)

Maintenance 

II

 (Cleaning)

Product Service

2
2

2-3

3
3

3-4
5-8

9

10-13

14
14
15
16

Pages

Summary of Contents for FV-07VQL3

Page 1: ... injury and or property damage Please retain this booklet for future reference Table of Contents List of components Description Dimensions Specifications Unpacking General safety Information Installation I Joist mounting Installation Installation II Wooden header Installation Installation III Between joist mounting Installation Installation IV ln existing construction Maintenance I Replacement of ...

Page 2: ...d produces almost the same illumination as a standard 100W incandescent lamp 2 FV 07VQL3 FV 08VQL3 FV 11VQL3 Unit mm inch FV 07VQL3 FV 08VQL3 FV 11VQL3 Grille Long screw M4 x 30 1 10 2 1 1 1 1 2 1 2 2 3 1 1 4 13W Fluorescent Lamp Plastic screw M4 x 13 4W incandescent lamp Spacer Short screw M4 x 12 6 200 7 7 8 45 1 7 8 22 7 8 16 5 5 8 79 3 1 8 117 4 5 8 350 430 13 7 8 17 550 640 22 25 34 1 1 8 32 ...

Page 3: ...ct OSHA Always disconnect the power source before working on or near the fan motor or light fixture 1 2 3 4 Grille Junction box Junction box cover Body Damper Night lamp connector 13W lamp connector 1 3 4 5 6 8 9 Motor connector 7 15 Lamp cover 16 Night lamp 17 Bracket cover Adapter 2 14 Fluorescent lamp 13W x 2 10 13 Light unit 12 Thumb screw 4W x 1 Model Air direction V Hz Power consumption W Fa...

Page 4: ...onstruction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and t...

Page 5: ...ke sure the adapter is level and square perpendicular with the joists Keep the distance B 21 6mm 0 85 inch for the thickness of ceiling board Fig 2 Fig 3 I CAUTION Remove the bracket cover by loosening 4 M4x6 screws before installation Fig 1 Fig 1 Fig 2 Fig 3 Fig 3 Bracket cover Fig 1 Disconnect plug connector from receptacle before starting installation Lead wires Conduit B Installation Joist mou...

Page 6: ...Motor Capacitor Black White Green Green Ballast Light unit Lamp Lamp Power supply AC 120V 60 Hz Earth ground Junction box Ballast WARNING Make all electrical connections in accordance with the National Electric Code NEC and all local electrical codes CAUTION Mount junction box cover carefully so that lead wires are not caught Ceiling joist mm inches 235 235 Adapter Ceiling 9 25 9 25 Tape Duct Adap...

Page 7: ...ceiling Mount blower section and fix with 3 screws IMPORTANT Make sure that frame is properly inserted into groove of blower section Secure fan body to adapter using two thumb screws 8 7 Fig 6 1 Fig 6 2 Fig 5 Fig 6 3 Fig 5 Insert fan body into ceiling Fig 6 1 Fig 6 2 Fig 6 3 Fig 5 Fig 7 Fig 7 Ceiling Body Claws Adapter slots Thumb screws Groove Frame section Frame section Blower section Screws Blo...

Page 8: ...ent lamps and screw the night lamp into the light unit Fig 10 11 12 Insert the lamp cover to the grille and attach the grille to the fan unit Fig 11 13 Fix fan body to ceiling joists using long screws M4X30 in horizontal or vertical direction Fig 9 10 Receptacle II Plug connector III Receptacle III for 13w lamp Plug connector II Receptacle III 4W Night Lamp Receptacle II for night lamp Receptacle ...

Page 9: ...o the Grille and attach the grille to the fan unit Fig 12 Fig 13 Fig 14 Fig 3 Fig 15 Fig 11 1 Mount junction box cover carefully so that lead wires are not caught CAUTION Junction box cover Circular duct Adapter When connecting the light unit and fan unit seperately read the note on page 6 before making connections Fig 12 Fig 13 3 4 5 6 7 8 Fig 14 mm inch Thumb screws Light unit Fan body Ceiling j...

Page 10: ...fan body by using two thumb screws 2 Insert the installation bracket III into slot of the adapter side III Fig 16 Fig 17 Fig 18 installation bracket I installation bracket IV Frame Fig 16 3 Insert the installation brackets I and IV into slot Fig 18 Fig 17 Fan body installation bracket III Fan body adapter ...

Page 11: ... the fan body to ceiling joists using long screws M4X30 in horizontal direction with installation bracket I and IV III CAUTION Fig 21 Fig 20 Fig 19 Joist spacing A should be between 350mm 13 7 8 and 430mm 17 Don t fix the junction box flap to the ceiling joist in this installation Fig 19 4 Long screws Installation bracket I Installation bracket IV Ceiling joist Installation bracket III Ceiling joi...

Page 12: ...junction box cover and secure conduit to junction box knockout hole 7 8 inch Refer to wiring diagram on page 6 Using wire nuts connect house power wires to ventilating fan wires Black to blacks white to whites green to greens Replace junction box cover 9 Mount junction box cover carefully so that lead wires are not caught CAUTION Fig 3 Fig 24 Adapter Junction box cover Circular duct Fig 23 Fig 23 ...

Page 13: ...n case Light unit Spacer Long screws Receptacle II Plug connector III Plug connector II Receptacle III Fig 27 Night lamp Spacer Insert the fluoresceut lamps and screw the night lamp into the light unit Fig 26 Light unit Fluorescent lamp Fig 27 Mounting spring Light unit Slot Grille Lamp Cover Grille 13 Insert the plug connector II and plug connector III Fig 26 into the receptacle II and receptacle...

Page 14: ...e Squeeze mounting spring and pull down Fig 28 Gloves Fig 29 Connector III Connector II Fig 30 Change the fluorescent bulbs Panasonic FDS 13E 27 U 2 13W or FQ13E 41 U 2 13W or FQ13E 35 U 2 13W orthe4Wincandescentlamp connect the connector II or connector III and replace the grille 3 Installation In existing construction IV Maintenance Replacement of fluorescent lamp or night lamp I Check area abov...

Page 15: ... parts to temperature over 140 F 60 C Remove grille Squeeze mounting spring and pull down Wash and clean grille Use non abrasive kitchen detergent Remove dust and dirt from fan body using a vacuum cleaner Remove bulbs if necessary Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with new cloth Replace bulbs and grille WARNING CAUTION 1 2 Fig 31 Fig 32 Fig 33 Fig...

Page 16: ...factured to ensure a minimum of maintenance However should your unit ever require service a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support your product s warranty In the U S A call 1 866 292 7292 to locate the Panasonic Authorized Service Center nearest you PANASONIC CONSUMER ELECTRONICS COMPANY PANASONIC CANADA INC One Panasonic Wa...