5

Fig.3

INSTALLATION FOR FV-07VBA1(JOIST MOUNTING)

Thermally - protected

(114    Fuse in motor)

C

Thermally - protected

(11

s

tor)

Fan body

Junction box

Black

Switch

I-Standard

II-Boost

Capacitor

Earth ground

AC120V  60Hz

Power supply

White

Live

Neutral

Motor

White

Red

Black

Black

White

Green

Yellow

Yellow

A

B

Fig.4

Switch

AD

APT

OR

JUN

CTIO

N B

OX

Fig.1

Tongue

Conduit

Junction

box

Earth ground

to green

Neutral to white

Live to black

Wire nut

Junction box cover

Fig.2

2. Install the ventilation duct and secure it with a clamp

     and seal it with mastic or approved foil tape. A 4 inch

     circular duct is needed to connect to the relevant

     part of adapter. (Fig. 2) 

Conduit

Junction box cover

4. Refer to wiring diagram.

    Follow all the local electrical safety codes as well

    as the National Electrical Code (NEC). Using UL 

    approved wire nuts, connect house power wires

    to ventilating fan wires.

6. Affix the junction box cover to junction box.
    If the knock-out hole is used  B  , this step 
    must be performed after step 8. 

7. Insert the tongue on the bottom of the 

    junction box so that it is on the outside of 

    the fan housing.

  8. Affix the junction box to the top of the 

       fan housing with screw     (ST4.2X8). (Fig.4)

Before affixing screw    (ST4.2X8), make 

sure the tongue of the junction box is 

clipped on fan housing correctly. (Fig.3)
Mount junction box cover carefully so

that lead wires are not pinched.

The clamps of the adaptor should b

clipped on fan housing correctly.

Install the adaptor and secure 

v

duct before installing

entilation 

junction box.

 

Mount junction box cover carefully so 

that the lead wires are not pinched.

INSTALLATION FOR FV-07VBA1 (JOIST MOUNTING)

6. Select the air volume speed by adjusting the 

     switch. Factory setting is “I” (Standard) position; preseting

     “II” (Boost) selects the high airflow position. (Fig. 4)

INSTALLATION FOR FV-07VBA1A (JOIST MOUNTING)

ST4.2X8 screw

Fig.3

A

Mount junction box cover carefully so 

that the lead wires are not pinched.

1. Affix the fan housing to joist 3 long screws 

    (ST4.2X20) by affixing first 1 screw on the bottom

    of the joist, hang up the fan housing through the 

    key hole, tighten the screw, then affix other 

    2 screws. (Fig. 1)

3. Remove screw ST4.2X8 from junction box cover

    and secure conduit or strain to knock-out hole

    (     or     ). (Fig. 3)

Junction box

cover

5. Affix the junction box cover to junction box with

    ST4.2X8 screw.

IMPORTANT:

Remove the tape from adapter before 

installation. As shown bellow:

Tape with 

ST4.2X20 screws

Damper

Adapter