Panasonic FV-0511VFL1 Installation Instructions Manual Download Page 1

PRACTICAL GUIDE TO INSTALLATION

BACK COVER

INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Thank you for purchasing this Panasonic product.
Please read these instructions carefully before attempting to install, operate or service
the Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION”. 
Failure to comply with instructions could result in personal injury or property damage. 
Please explain to users how to operate and maintain the product after installation, 
and this booklet should be presented to users.
Please retain this booklet for future reference.

FV-0511VFL1
FV-0511VFL1K

Ventilating Fan

Model  No.

Contents

GENERAL SAFETY INFORMATION
DESCRIPTION
UNPACKING
SUPPLIED ACCESSORIES
DIMENSIONS
WIRING DIAGRAM
FEATURES
INSTALLATION (RETROFIT)
INSTALLATION (NEW CONSTRUCTION)
MAINTENANCE (CLEANING)

SPECIFICATIONS
PRODUCT SERVICE

----------------- 2~3

---------------------------------------- 4

------------------------------------------ 4

---------------------------- 4

----------------------------------------- 5

------------------------------------ 5

----------------------------------------- 5~6

------------------------ 6~8

---------- 9~11

------------------------- 11

---

-------------------------

---------------------- BACK COVER

BACK COVER

5 1 1 F L 1 4 2 0

Summary of Contents for FV-0511VFL1

Page 1: ...esult in personal injury or property damage Please explain to users how to operate and maintain the product after installation and this booklet should be presented to users Please retain this booklet for future reference FV 0511VFL1 FV 0511VFL1K Ventilating Fan Model No Contents GENERAL SAFETY INFORMATION DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURES INSTALLATION RE...

Page 2: ... the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation w...

Page 3: ... method which is not approved in the instructions Do not install this ventilating fan in a location where the interior room temperature may exceed 104 F 40 C This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmonic distortion which can cause a humming noise in the motor Follow all local electrical and safety codes ...

Page 4: ...of North America Two Riverfront Plaza Newark NJ 07102 Customer Call Center 1 866 292 7299 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Type IC Inherently Protected Reorient or re...

Page 5: ... 5 8 143 10 3 4 271 2 3 4 69 7 2 7 8 71 4 1 3 8 32 6 1 1 2 37 13 330 9 10 13 330 8 3 7 8 96 7 5 5 8 140 12 1 8 307 1 5 6 3 7 2 Duct length elbows and other factors increase static pressure which can hinder the performance of most ventilation fans These products utilize SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depe...

Page 6: ... Adjustable color temperature switch CFM 50 80 110 Lighting option K 3000 4000 5000 4000 K Factory setting FEATURES CONTINUED Remove the tape placed on the damper and adaptor before installation Flex Z Fast bracket 2 The Flex Z Fast bracket position can be adjusted from 16 to 24 between joists Install Flex Z Fast bracket WARNING Disconnect power supply before installing the unit Tape Adaptor Dampe...

Page 7: ...ectrical safety codes as well as the National Electrical Code NEC Use UL approved wire connectors to connect fan wires After connecting wires replace junction box cover 1 Junction box cover 1 2 Joist Adaptor INSTALLATION RETROFIT CONTINUED 1 Install the adaptor to the Flex Z Fast bracket by using 2 self drilling screws 1 Install adaptor 2 Self drilling screws Circular exhaust duct Conduit 1 Self d...

Page 8: ...Step 6 to avoid cross threading and to ensure that the screw does not strip or come in contact with the Flex Z Fast bracket 2 Secure fan body Once fan body is mounted and secure fill gap between flange and ceiling with caulk or other sealant to prevent air leakage Insert the mounting springs into the slot as shown to mount grille to fan body 1 Adjust Pick A Flow switch Refer to explanation under F...

Page 9: ...wire connectors to connect fan wires After connecting wires replace junction box cover Install circular exhaust duct 2 Self drilling screws 2 3 1 1 2 3 Connecting wires A 2 Tapping screws ST4 2X20 Bend down 4 tabs and align bracket to the joist Extend bracket to the other joist Circular exhaust duct Conduit Junction box cover 1 INSTALLATION NEW CONSTRUCTION Please remove the tape placed on the dam...

Page 10: ...ighting option required by the owner FV 0511VFL1K only Refer to explanation under FEATURES Page 6 1 1 Mounting spring Adjustable color temperature switch Drywall Once fan body is mounted and secure fill gap between flange and ceiling with caulk or other sealant to prevent air leakage 1 Adjust Pick A Flow switch Refer to explanation under FEATURES Page 6 2 When the flange overlaps the Flex Z Fast b...

Page 11: ...nd dirt from fan body using a vacuum cleaner NOTE The grille should be dry after cleaning 1 2 3 2 Remove grille 1 Gloves Slot Grille Mounting spring Clean grille Don t put into hot water Use non abrasive kitchen detergent wipe dry with clean cloth 1 1 3 2 Maintenance of unit Disconnect the wire from the receptacle then pull down the other mounting spring Gloves Drywall Vacuum cleaner Gloves Drywal...

Page 12: ...qualified technicians only Your product is designed and manufactured to ensure a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA minimize building heat loss and gain Loose fill or batt insulation can be placed directly over the fan housing in the attic Panasonic fans do not create excessive heat which is a common problem with recess...