11. 

 (Fig.9)

Insert the grille mounting spring on the wiring 

      side into the slot.

12. 

(Fig.9).

Plug in the specified devices as your choice 

      (refer to installation on page 8). Insert the 
      motion sensor (FV-MSVK1 only) or LED night 
      light (FV-NLVK1 only) into slot of the grille. 
      Fix the lead wire into the clasp 

9

8. Insert fan body and slide into adapter assy with 
    some strength, untill the flange overlaps the 

 

TM

    Flex-Z Fast

bracket. Secure the fan body to 

 

TM

    Flex-Z Fast

bracket by using 2 self-drilling screws, 

    plug connector to receptacle and secure the fan 
    body to adaptor by using machine screw (M4X6). 
    (Fig.6)

Mount junction box cover carefully so that 
lead wires are not pinched.

Secure machine screw (M4X6) to 

TM

hole and not touch the Flex-Z Fast  bracket. 
Please fix the screw carefully to avoid screw 
slip teeth.

the suitable 

10. Remove the tapes from louver and springs
      before installation. (Fig.8)

7. Refer to wiring diagram on page 5.
    Follow all the local electrical safety codes as well
    as the National Electrical Code (NEC).
    Using UL approved wire nuts, connect house 
    power wires to ventilating fan wires. (Fig.5)

Fig.5

FV-05-11VKS1
FV-05-11VK1
FV-11-15VK1

Wire nut

Conduit

Live to black

Netural to white

Junction 
box

Two red wires
(Connect to a general 
manual wall switch)

Earth ground 
to green

INSTALLATION (NEW CONSTRUCTION) CONTINUED

9. Finish ceiling work. Ceiling hole should be aligned
    with the inside edge of the flange. (Fig.7) 

Tapes

10 1/2 

(270)

10 1/2 

(270)

Fig.7

Fig.9

Fig.8

Unit: inches (mm)

After finishing the ceiling job, fill gap between flange
and ceillng with caulk or other sealant to prevent air
leakage

Ceiling

Fig.6

Machine 
screw

 

(M4X6)

2 Self-drilling 
screws

Joist

Plug connector

Receptacle

Motion sensor
(FV-MSVK1 only)

LED night light
(FV-NLVK1 only)

Clasp

Ceiling

IMPORTANT:

Replace the sensor cover before the installation 
(only for plug-in Motion sensor modular FV-MSVK1).  
As shown below:

Keep on pressing the clasps when removing the ornamental cover.

Sensor 
cover

Insert the sensor cover (attachment for FV-MSVK1) into slot.

Gloves

Ornamental 
cover

Summary of Contents for FV-05-11VKS1

Page 1: ...IPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURE INDICATION PLUG N PLAY FUNCTION DEVICES MOTION PLUG N PLAY FUNCTION DEVICES INSTALLATION PLUG N PLAY FUNCTION DEVICES INSTALLATI...

Page 2: ...d shower enclosures For Your Safety To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions Explan...

Page 3: ...r dedicated parts such as mounting fixtures must be used if such parts are provided Do not install the unit where ducts are configured as shown in Fig A Adaptor CAUTION Canada only Not to be installed...

Page 4: ...100 105 110 Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms DESCRIPTION These products are listed by UL under UL file No E78414 These products use a sirocco fan driven by a DC motor powered b...

Page 5: ...V 11 15VK1 4 5 8 116 7 8 22 5 1 26 FV 11 15VK1 10 11 12 11 FV 05 11VKS1 Unit inches mm 13 330 3 1 4 81 3 1 2 88 7 3 8 190 6 3 8 163 5 7 8 148 5 7 8 148 3 7 8 98 10 1 4 260 12 1 8 307 10 1 4 260 3 7 8...

Page 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM M...

Page 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Page 8: ...plug connector from receptacle and remove adaptor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As sh...

Page 9: ...page 5 Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 Fig 5 FV 05 11VKS1...

Page 10: ...1 Remove the existing fan and cut ceiling openning 2 Follow the step 1 4 5 on page 8 and step 7 on page 9 Before connect the circular duct to the adaptor should pull down the circular duct from the c...

Page 11: ...FV MSVK1 or FV NLVK1 Pull down the mounting spring that without lead wire passed side and remove motion sensor or LED night light as shown in Fig 16 Squeeze mounting spring and pull down carefully Dis...

Page 12: ...d directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light...

Reviews: