Panasonic FV-05-11VK1 Installation Instructions Manual Download Page 1

FV-05-11VKS1
FV-05-11VK1
FV-11-15VK1

Model  No.

Thank  you  for  purchasing  this  Panasonic  product.

FV-05-11VKS1    FV-05-11VK1

FV-11-15VK1

GENERAL SAFETY INFORMATION

PLEASE READ PRIOR TO INSTALLING THIS FAN

DESCRIPTION

UNPACKING

SUPPLIED ACCESSORIES

DIMENSIONS

WIRING DIAGRAM

FEATURE

INDICATION (PLUG ‘N PLAY FUNCTION DEVICES)

DESCRIPTION FOR NIGHT LIGHT MODULE

MOTION (PLUG ‘N PLAY FUNCTION DEVICES)

INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES)

INSTALLATION (NEW CONSTRUCTION)

INSTALLATION (RETROFIT)

MAINTENANCE (CLEANING)

PRACTICAL GUIDE TO INSTALLATION

SPECIFICATIONS

PRODUCT SERVICE

Contents

2-3

4

4

4

5

5

5

5-6

6-7

7

7

8

8-10

10

11

BACK COVER

BACK COVER

BACK COVER

Summary of Contents for FV-05-11VK1

Page 1: ...PPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURE INDICATION PLUG N PLAY FUNCTION DEVICES DESCRIPTION FOR NIGHT LIGHT MODULE MOTION PLUG N PLAY FUNCTION DEVICES INSTALLATION PLUG N PLAY FUNCTION DEVICES INSTALLATION NEW CONSTRUCTION INSTALLATION RETROFIT MAINTENANCE CLEANING PRACTICAL GUIDE TO INSTALLATION SPECIFICATIONS PRODUCT SERVICE Contents 2 3 4 4 4 5 5 5 5 6 6 7 7 7 8 8 10 10 11 BACK COV...

Page 2: ...nd shower enclosures For Your Safety To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard injury and property damage caused when the denotation is disregarded and improper us...

Page 3: ...or dedicated parts such as mounting fixtures must be used if such parts are provided Do not install the unit where ducts are configured as shown in Fig A Adaptor CAUTION Canada only Not to be installed in a ceiling thermally insulated to a value greater than R40 Do not disassemble the unit for reconstruction It may cause fire or electric shock Ceiling joist must be subjected to static load more th...

Page 4: ...5 100 105 110 Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms DESCRIPTION These products are listed by UL under UL file No E78414 These products use a sirocco fan driven by a DC motor powered by an integral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remo...

Page 5: ...330 2 4 1 3 5 7 8 TM Flex Z Fast bracket with 4 tapping screws ST4 2X20 1 Multi Speed module FV 05 11VKS1 only other models not included Plug N Play module slot Plug N Play module slot Power switch Fan body DC Motor Junction box Black Live Neutral Power supply AC120V 60Hz Red Red Green Earth ground Green White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module On Off swit...

Page 6: ...before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70 90 100 110 110 Factory setting 20 minutes Delay Time position 0 Manual wall switch control is 0 minute without manual...

Page 7: ...OFF 20 minutes time delay FV MSVK1 only Fan active At low speed When motion or excess humidity is detected fan runs at high speed Remains running at high speed until the delay time has passed FV CSVK1 FV VS15VK1 Fan Hi Low speed Depend on FV VS15VK1 Time delay setting FV MSVK1 FV VS15VK1 Please note that if plan to use the FV NLVK1 Nite Glo LED Night Light module it is recommended to control the f...

Page 8: ...body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from 16 to 24 on center can be adjusted flexibly 2 Bend down 4 tabs for positioning install the TM Flex Z Fast bracket to joists by drilling 2 tapping screws which have been fixed on it Fig 2 TM 3 Adjust the length of...

Page 9: ...page 5 Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 INSTALLATION NEW CONSTRUCTION CONTINUED 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 Tapes 10 1 2 270 1 0 1 2 2 7 0 Fig 7 Fig 9 Fig 8 Unit inches mm After finishing the c...

Page 10: ...he step 1 4 5 on page 8 and step 7 on page 9 Before connect the circular duct to the adaptor should pull down the circular duct from the ceiling Disconnect power source before working on unit 5 Follow the step 10 to 14 on page 9 to 10 TM Secure the Flex Z Fast bracket to joists by drilling 4 tapping screws ST4 2x20 which have been fixed on it Existing ductwork and wiring left in place Fig 12 TM 3 ...

Page 11: ... FV MSVK1 or FV NLVK1 Pull down the mounting spring that without lead wire passed side and remove motion sensor or LED night light as shown in Fig 16 Squeeze mounting spring and pull down carefully Disconnect power source before working on unit WARNING CAUTION Fig 16 Fig 15 Mounting spring Gloves Slot Grille Motion sensor FV MSVK1 only LED night light FV NLVK1 only Routine maintenance must be done...

Page 12: ...ombination Our efficient cool running motors and our LED lighting unit do not create enough ambient heat to be subjected to these limitations HVI Certified performance based on HVI Procedures 915 916 and 920 Specifications for Multi Speed fans Model No Model No Air direction Air direction Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones S...