background image

Summary of Contents for FV-04WS2

Page 1: ...CAL GUIDE TO INSTALLATION 11 SPECIFICATIONS 11 PRODUCT SERVICE BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you very much for having purchased our product Please read these instructions carefully before attempting to install operate or service the Panasonic product Failure to comply with instructions could result in personal injury or property damage Please explain to users how to operate and...

Page 2: ... alert users to a specific operating procedure that must not be performed This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal AWARNING o 0 0 To reduce the risk of fire electric shock or injury to persons observe the following Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer...

Page 3: ... 20V 60 Hz Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor or junction box Protect the supply wiring from sharp edges oil grease hot surfaces chemicals or other objects Do not kink the supply wiring The wall must be subjected to static lo...

Page 4: ...er will act as a damper to prevent unintended air entry These ventilating fans are equipped with a filter which is replaceable UNPACKING Unpack and carefully remove the unit from carton Refer to the supplied accessories list to verify that all parts are present SUPPLIED ACCESSORIES Part name Appearance Quantity Screw I M4X10 33 2 Screw II ST4 2X20 8 Installation instructions 2 Warranty sheet 1 ACA...

Page 5: ...95 2 3 16 55 8 203 6 7 8 174 5 15 16 151 6 13 16 173 5 13 16 148 Model J K L M N O P Q FV 01WS2 6 1 4 159 3 7 8 98 6 152 6 7 8 174 5 1 2 140 4 7 16 113 1 1 16 17 3 5 8 92 FV 04WS2 83 16 208 5 13 16 148 63 16 157 87 16 215 7 5 16 186 5 1 4 134 11 16 17 59 16 142 WIRING DIAGRAM FV 01WS2 Fan body Red 0 5HF Junction box Switch Capacitor Motor white 3 Black 114 C Fuse in Motor Impedance protected White...

Page 6: ... line are not run and there are not studs in the way 2 Separate the product to main unit duct unit and hood unit Fig 2 3 Unscrew two screws lower the junction box into the duct and pull it out from duct unit Fig 3 Insert the duct unit into wall and secure it to the drywall or other wall covering by screw II ST4 2X20 in accessory Fig 4 Before installation adjust the direction of the duct unit in ac...

Page 7: ...rew Fig 8 ACAUTION Mount junction box cover carefully so that lead wires are not pinched 9 Reinstall junction box back into duct unit by using screws Fig 9 1 0 Detach the panel from fan body by pushing up and pulling outward the tab at the base of the panel Fig 10 11 Open the cover in the top right corner of the fan body to allow the junction box pigtail and plug to come through Insert the plastic...

Page 8: ...shutter Fig 13 ACAUTION Stop the fan while closing the shutter Open the shutter while running the fan 1 4 Detach hood and hood base by loosening the screw Fig 14 15 Insert duct collar into duct and adjust the upper edge of hood base to horizontal Secure hood base by using screwll ST4 2x20 in accessory and seal the gap between the wall and hood base by sealant Fig 15 16 Install hood on hood base an...

Page 9: ...ark The upper edge should keep horizontal 4 Finish indoor installation following step 5 1 of installationl Page 6to 8 5 Detach hood following step 14 of installationl Page 8 Press buckle on hood base and detach duct collar after loosening three buckles Fig 19 6 Pull flexible duct to a suitable length through the hood base Keep the upper edge of hood base horizontal and secure it by 4 screwll ST4 2...

Page 10: ...detach the panel by pushing up thetab Fig 23 2 Remove dust and dirt inside the panel by using a vacuum cleaner Clean the surface of the panel with non abrasive kitchen detergent and wipe dry with clean cloth Please do not immerse panel in water while cleaning Fig 24 3 Squeezethe buckle of the filter and detach it Remove dirt from it by using a vacuum cleaner Fig 25 When replacing the filter please...

Page 11: ...g 29 Loose fill or batt insulation can be placed directly over the duct in the wall Interior wall covering X Fan body Indoor Exterior wall siding Hood Outdoor Fig 29 SPECIFICATIONS Model No Duct diameter inches Air direction Voltage V Frequency Hz Noise sones Power consumption W Speed r min Air volume at 0 03 WG CFM Weight Ib kg FV 01WS2 4 Intake 120 60 0 3 3 0 2590 10 5 3 2 4 FV 04WS2 6 Intake Hi...

Page 12: ...mum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Panasonic Corporation of North America Two Riverfront Plaza Newark NJ 07102 www panasonic com Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic ca Panasonic corporation 201 Printed in China T0214 01WS24010 ...

Reviews: