20.2 List of System Data Registers
SD0-SD28
Device
No.
Name
Description
SD0
Self-diagnostic error code
Stores the error code when a self-diagnosis error occurred.
SD1
Alarm Occurrence Unit Slot
No.
Saves the slot number of the unit where an alarm has occurred.
Slot No.1 to 64
SD2
Error Occurrence Unit Slot
No.
Stores the slot number of the unit in which the error occurred or the
slot number of the CPU unit with built-in ET-LAN.
Slot No.1 to 64, 100 (CPU unit with built-in ET-LAN)
SD3
Warning Occurrence Unit Slot
No.
Stores the slot number of the unit in which the warning occurred or
the slot number of the CPU unit with built-in ET-LAN.
Slot No.1 to 64, 100 (CPU unit with built-in ET-LAN)
SD4
Verification Error Occurrence
Unit Slot No.
Saves the slot number of the unit where a verification error has
occurred.
Slot No.1 to 64
SD5
Installation error detection
slot No.
Saves the slot number of the unit where an installation error was
detected.
Slot No.1 to 64
SD6
Memory configuration
inconsistency details
When a memory configuration inconsistency is detected, information
about the setting where the error has occurred is saved
Bit No.
Description
0
Logging/Trace settings
1
FTPc settings
2
HTTPc settings
3
Mailc settings
4
EIP settings
5
W-PLC link settings
6
W2-PLC link settings
SD7
Operation error occurrence
PB number (hold type)
Saves the PB number where the first operation error occurred after
the unit has started operating.
SD8
Address with operation error
(hold type)
(32-bit lower address)
Saves the address where the first operation error occurred after the
unit has started operating. Perform monitoring using 32-bit data.
SD9
Address with operation error
(hold type)
(32-bit higher address)
SD10
Operation error occurrence
PB number (latest type)
Saves the PB number where an operation error occurred. Every time
a new error occurs, the data are updated. The value '0' is recorded
at the start of the scan.
SD11
Address with operation error
(new type)
(32-bit lower address)
Saves the address where an operation error occurred. Every time a
new error occurs, the data are updated. The value '0' is recorded at
the start of the scan. Perform monitoring using 32-bit data.
20.2 List of System Data Registers
WUME-FP7CPUPGR-12
20-9
Summary of Contents for FP7 Series
Page 2: ... MEMO 2 WUME FP7CPUPGR 12 ...
Page 18: ... MEMO xviii WUME FP7CPUPGR 12 ...
Page 52: ... MEMO 1 34 WUME FP7CPUPGR 12 ...
Page 104: ... MEMO 2 52 WUME FP7CPUPGR 12 ...
Page 123: ...3 9 ANS AND stack WUME FP7CPUPGR 12 3 19 ...
Page 125: ...3 10 ORS OR Stack WUME FP7CPUPGR 12 3 21 ...
Page 129: ...3 11 PSHS Push stack RDS Read stack POPS Pop stack WUME FP7CPUPGR 12 3 25 ...
Page 190: ...3 26 JP LBL Jump Label 3 86 WUME FP7CPUPGR 12 ...
Page 239: ...Name Description SR8 ER 3 46 ST ST ST ST ST ST Data Comparison Start WUME FP7CPUPGR 12 3 135 ...
Page 246: ... MEMO 3 142 WUME FP7CPUPGR 12 ...
Page 258: ... MEMO 4 12 WUME FP7CPUPGR 12 ...
Page 304: ... MEMO 5 46 WUME FP7CPUPGR 12 ...
Page 321: ...Name Description ER 6 7 DIVFP2 Division FP2 Compatible WUME FP7CPUPGR 12 6 17 ...
Page 348: ... MEMO 6 44 WUME FP7CPUPGR 12 ...
Page 388: ... MEMO 7 40 WUME FP7CPUPGR 12 ...
Page 438: ... MEMO 8 50 WUME FP7CPUPGR 12 ...
Page 450: ... MEMO 9 12 WUME FP7CPUPGR 12 ...
Page 520: ... MEMO 10 70 WUME FP7CPUPGR 12 ...
Page 602: ... MEMO 11 82 WUME FP7CPUPGR 12 ...
Page 622: ... MEMO 12 20 WUME FP7CPUPGR 12 ...
Page 650: ... MEMO 13 28 WUME FP7CPUPGR 12 ...
Page 1160: ... MEMO 18 66 WUME FP7CPUPGR 12 ...
Page 1188: ... MEMO 19 28 WUME FP7CPUPGR 12 ...
Page 1220: ... MEMO WUME FP7CPUPGR 12 ...
Page 1221: ... MEMO WUME FP7CPUPGR 12 ...