5.4 Wiring of MIL Connector Type
Supplied connector and suitable wires
The connector listed below is supplied with the unit. Use the suitable wires given below. Also, use the
required pressure connection tools for connecting the wires.
Suitable wires (Twisted wire)
Size
Nominal cross-sectional
area
Insulation thickness Remark
Rated current
AWG#22
0.3mm
2
Dia. 1.5 to dia. 1.1
Twisted wire of
12 pcs/0.18
3A
AWG#24
0.2mm
2
Twisted wire
Note) The contact suitable for AWG#22 or AWG#24 is supplied with the product. For purchasing a
contact suitable for AWG#26 or AWG#28, specify AXW7231FP.
Connector for loose-wire cable (Attached to the control unit and expansion I/O unit)
Manufacturer
Type and product No.
Unit type and required quantity
E8
C16/E16
C32/T32/F32/E32
Manufactured by us
Housing(10P)
1 pc
2 pcs x 1 set 2 pcs x 2 sets
Semi-cover(10P)
2 pcs
4 pcs x 1 set 4 pcs x 2 sets
Contact (for AW22 and 24)
5 pins
2 pcs x 1 set
4 pcs x 1 set 4 pcs x 2 sets
Note) The parts of the number of the connectors are supplied with the product. If you need more
connectors, purchase AFP0807 (2 sets/pack).
Pressure connection tool
Manufacturer
Product No.
Manufactured by us
AXY52000FP
Key Point:
When using a MIL connector for flat cables, purchase the product number AFP0808 (4 pcs, 10-pin
strain-relief with key). In this case, the suitable wire is AWG#28 and the rated current is 1A.
Summary of Contents for FP0R Series
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 24: ...1 10 ...
Page 25: ...Chapter 2 Specifications and Functions of Control Unit ...
Page 38: ...2 14 ...
Page 39: ...Chapter 3 Expansion ...
Page 45: ...3 7 3 4 Terminal layout diagram Model No Terminal layout diagrams E8RS E8RM E16RS E16RM E8YRS ...
Page 48: ...3 10 ...
Page 49: ...Chapter 4 I O Allocation ...
Page 53: ...Chapter 5 Installation and Wiring ...
Page 73: ...Chapter 6 Preparation of USB Port ...
Page 77: ...6 5 5 Click Finish on the following screen to be displayed ...
Page 79: ...6 7 4 Double click on FP0R 5 Click Update Driver ...
Page 84: ...6 12 ...
Page 85: ...Chapter 7 Communication ...
Page 139: ...7 55 Sample program For Type II Use a program as below to directly specify a MODBUS address ...
Page 141: ...Chapter 8 High speed Counter Pulse Output and PWM Output Functions ...
Page 142: ...8 2 ...
Page 199: ...Chapter 9 Security Functions ...
Page 211: ...Chapter 10 Other Functions ...
Page 217: ...Chapter 11 Self Diagnostic and Troubleshooting ...
Page 227: ...Chapter 12 Precautions During Programming ...
Page 242: ...12 16 ...
Page 243: ...Chapter 13 Specifications ...
Page 254: ...13 12 ...
Page 255: ...Chapter 14 Dimensions and Others ...
Page 262: ...14 8 ...
Page 263: ...Chapter 15 Appendix ...
Page 344: ...15 82 15 7 ASCII Codes ...
Page 346: ......
Page 347: ......
Page 348: ......