Error/Warning Annunciation Function
19-18
19.3.5 Set Value Errors (4000H - )
The following errors occur to various set values made in the positioning setting menu of the
programming tool and ladder programs.
Code Name
Description
Object Recovery Measures
4000H
Axis group
setting error
The axis group setting is
abnormal.
When using the virtual axes, the
virtual axes are not registered in
the independent axis area of the
axis group.
Each
axis
○
Check settings of the axis group
and individual axis as follows.
- The same axis no. is registered
in multiple groups.
- More than 4 axes are set in the
same group.
- The axis group comprises only
1 axis.
- The virtual axes are not
registered in the independent
axis area of the axis group.
4001H
Virtual axis
setting error
The virtual axis usage setting
(number of virtual axes) is
incorrect.
All axes
○
Check the setting.
4002H
Unit setting
error
The unit system for the axis
setting is out of the range.
Each
axis
○
Check if the unit is one of the
followings.
pulse,
µ
m, inch, degree
4004H
Pulse number
error per
rotation
The pulse number is out of the
range.
Each
axis
○
Check the set value.
If the set value is out of the
range, reduce it by the following
formula.
(Pulse number per rotation) /
(Movement amount per rotation)
4005H
Movement
amount error
per rotation
The movement amount is out of
the range.
Each
axis
○
4010H
Software limit
setting error
The upper or lower limit value of
software limit is out of the range.
Each
axis
○
Check the set value.
If an error occurs repeatedly with
the correct set values, consult
your Panasonic representative.
4020H
Limit stop
deceleration
time error
The limit stop deceleration time
is out of the range.
Each
axis
○
4021H
Error stop
deceleration
time error
The error stop deceleration time
is out of the range.
Each
axis
○
4022H
Emergency
stop
deceleration
time error
The emergency stop
deceleration time is out of the
range.
Each
axis
○
4028H
Auxiliary
output setting
error
The settings of auxiliary output
are not correct.
A mode other than With mode or
Delay mode for the auxiliary
output mode has been set.
The auxiliary output delay ratio
while the positioning unit is in
Delay mode is not 0 to 100 (%).
Each
axis
○
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......