19.1 Errors and Warnings
19-3
19.1.3 Check and Clearing with User Program
Confirmation of Error/Warning message
•
The message is read via the special instruction PERED (Error/Warning obtained). When
executing F388 PERRD instruction, in addition to error code and warning code, the code
saved in buffer 1 will be read.
R100
F388 PERRD
DT100
H0
(
)
DF
Axis 1
Axis 1 error/warning read
Error and warning codes are saved as follows.
DT100
Error code
DT101
Warning code
Clear of all axes is performed via UCLR instruction
•
Error and warning occurred in the all axes of control unit can be cleared by executing the
special instruction UCLR (Error/Warning cleared).
F389 UCLR
R100
Unit clearing
request
)
DF
(
Clear for each axis via the I/O signal
•
When the Error/Warning clear request flag assigned to I/O area is ON, the Error/Warning of
each axis can be cleared individually. The following is the program for clearing the error.
R100
Clear error
request
Axis 1 error
clearing flag
X1230
Axis 1 error
notification flag
Y1230
DF
Y1230
Axis 1 error
clearing flag
(
)
Allocation of I/O signals
Signal name
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7
(virtual)
Axis 8
(virtual)
Error annunciation
X1230
X1231
X1232
X1233
X1234
X1235
X1236
X1237
Warning annunciation
X1240
X1241
X1242
X1243
X1244
X1245
X1246
X1247
Error clear request
Y1230
Y1231
Y1232
Y1233
Y1234
Y1235
Y1236
Y1237
Warning clear request
Y1240
Y1241
Y1242
Y1243
Y1244
Y1245
Y1246
Y1247
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......