15.2 Setting and Operation of Pulsar
15-9
15.2.2 Settings for Pulsar Operation
For using the pulsar operation, set the parameters in the two dialog boxes "Pulse input" and
"Parameter settings" of Configurator PM7.
Pulse input setting
Select "Pulsar" from the items of pulse input application.
Item
Setting example
Settable range
Pulse input application
0: Pulsar
0: Pulsar
Pulse input rotation
direction
0: Forward
0: Forward, 1: Reverse
Pulse input method
0: 2-phase input
When using the pulsar, only "0: 2-phase input" can be set.
Pulse input multiplication
2: Multiply by 4
When using the pulsar, only "2: Multiply by 4" can be set.
Parameter settings menu
•
For the item of the "pulsar operation code" of the axis on which the pulsar operation is
performed, select the channel number of the connected pulse input.
•
The movement amount per an 1-pulse signal from the pulsar can be changed by setting the
ratio numerator and ratio denominator for the input signal of the pulsar.
Item
Setting example
Settable range
Operation setting code
0: Pulse input CH1
0: Pulsar input CH1, 1: Pulsar input CH2, 2: Pulsar input
CH3, 3: Pulsar input CH4
Pulsar operation ratio
numerator
2
1-32,767
Pulsar operation ratio
denominator
1
1-32,767
Pulsar input method
2: Speed restriction (time
hold)
0:Standard operation , 1: Speed restriction (pulse hold), 2:
Speed restriction (time hold)
Pulsar operation maximum
speed
500
pulse: 0 -2,147,482,624 pps
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......