1-2
1.1 Features and Functions of the Unit
Powerful control capabilities
All of the functions of a mid-scale PLC are packed into the compact body size of the 32-pont type FP0. A
program capacity of 12k steps or 32k steps is provided as a standard feature, so you never have to
worry about how much memory is left as you’re programming. In addition, 32k words are reserved for
data registers, so large volumes of data can be compiled and multiple operations can be processed
without running out of memory.
A full range of communication functions
Using the Tool port (RS232C) provided as a standard feature on the main unit, communication can be
carried out with a display panel or computer. Additionally, communication cassettes with RS232C and
RS485 interfaces are available as an option. Installing a 2-channel RS232C type communication
cassette in the FP
Σ
makes it possible to connect two devices with RS232C port. A full lineup of
communication functions means you can also work with 1:N communication (up to 99 units) and
PC(PLC) link function (up to 16 units).
Controlling two devices with RS232C port with one FP
Σ
When using the 2-channel RS232C type communication cassette
1:N communication possible with up to 99 stations (units)
When using the 1-channel RS485 type communication cassette
When using the 1-channel RS485 and 1-channel RS232C in combination
Summary of Contents for FP E Series
Page 1: ......
Page 16: ......
Page 17: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 28: ...1 12 ...
Page 29: ...Chapter 2 Specifications and Functions of the Unit ...
Page 37: ...2 9 Circuit diagram C32 Y0 Y1 Y3 Y4 C28 Y0 Y1 Y3 Y4 Y2 Y5 to YF Y2 Y5 to YB ...
Page 48: ...2 20 ...
Page 49: ...Chapter 3 Expansion ...
Page 56: ...3 8 Terminal layout diagram Note The numbers in the connector are for the first expansion ...
Page 61: ...Chapter 4 I O Allocation ...
Page 66: ...4 6 ...
Page 67: ...Chapter 5 Installation and Wiring ...
Page 90: ...5 24 ...
Page 91: ...Chapter 6 High speed counter Pulse Output and PWM Output functions ...
Page 116: ...6 26 ...
Page 121: ...6 31 ...
Page 125: ...6 35 Pulse output diagram ...
Page 131: ...6 41 ...
Page 139: ...6 49 ...
Page 141: ...6 51 ...
Page 144: ...6 54 Program Continued on the next page ...
Page 145: ...6 55 ...
Page 147: ...6 57 Program ...
Page 151: ...Chapter 7 Communication Cassette ...
Page 210: ...7 60 The values of DT50 and DT51 are written in DT0 and 1 of PLC ...
Page 238: ...7 88 ...
Page 239: ...Chapter 8 Self Diagnostic and Troubleshooting ...
Page 247: ......
Page 248: ......
Page 249: ...Chapter 9 Precautions During Programming ...
Page 260: ...9 12 Example 2 Using the CT instruction between JP and LBL instructions ...
Page 268: ...9 20 ...
Page 269: ...Chapter10 Specifications ...
Page 286: ......
Page 287: ...Chapter 11 Dimensions ...
Page 290: ...11 4 11 1 3 Expansion Unit FPG XY64D2T FPG XY64D2P FPG EM1 ...
Page 293: ...Chapter 12 Appendix ...
Page 297: ...12 5 ...
Page 437: ...12 145 12 7 ASCII Codes ...
Page 439: ......
Page 440: ......