E
NGLISH - 41
Maintenance
TEMP, LAMP and ARF Indicators
If a problem should occur with the projector, the
TEMP
,
LAMP
and/or
FILTER
indicators will inform you. Manage the indicated problems as
follow.
1. Confirm the status of all indicators and projector, and switch off the
projector in proper way.
2. Find out the cause of the problem by status of the
TEMP
,
LAMP
and/or
FILTER
indicators.
3. Follow the instruction for each indication below and solve the
problem.
4. Turn on the projector in the correct way and confirm the indicator is
not indicating a problem any longer.
J
LAMP indicator
J
TEMP indicator
J
FILTER indicator
When the
ARF
indicator is flashing
GREEN
, the
ARF
is normally rolling up.
Managing the indicated problems
NOTE:
• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center.
Indicator
Illuminating
RED
Flashing
RED
Problem
LAMP RUNTIME
has
reached 2 800 hours.
LAMP
circuit failure, abnormal function or
Lamp unit
is damaged.
Cause
Lamp unit
will run out
soon and needs to be
replaced.
The
MAIN POWER
is
switched on again
before the
Lamp unit
is cooled enough.
LAMP
circuit failure,
abnormal function.
Lamp unit
is
damaged.
Remedy
See “Replacing the
Lamp unit” on page 43.
Let the
Lamp unit
cool
down and turn on the
MAIN POWER
.
Contact an Authorized
Service Center.
See “Replacing the
Lamp unit” on page 43.
Indicator
Illuminating
RED
and still projecting
Flashing
RED
and
POWER
is turned off
Problem
The temperature inside and/or outside the projector is abnormally high.
Cause
The ventilation
openings are covered.
The room temperature
is too high.
The
ARF
is excessively
dirty and the ventilation
is poor.
The projector is located
at high elevations
(above 1 400 m).
Remedy
Remove the object(s)
from the ventilation
openings or clear
around the projector.
Reinstall the t a
temperature controlled
place. See page 16.
Replace the
ARF
in the
proper method. See
page 42.
Turn on the projector
*1
and set the
HIGHLAND
to
ON
.
See page 38.
*1. The projector will perform only 2 minutes with
OFF
setting at high elevation.
Indicator
Illuminating
RED
Flashing
RED
Illuminating
ORANGE
Flashing
ORANGE
Problem
FILTER REMAINING
has turned red. See
page 37.
The projector cannot
detect the
ARF
.
The
ARF
cannot
operate properly.
FILTER REMAINING
has turned yellow. See
page 37.
Cause
ARF
has been run out.
ARF
is not attached.
Foreign object is
blocking the
ARF
operation.
ARF
is running out.
Remedy
See “Replacing the
ARF (Auto Rolling
Filter)” on page 42.
Attach the
ARF
.
Remove the foreign
object or contact an
Authorized Center.
Prepare the
ARF
for
replacement.
POWER LAMP
ARF
TEMP