12
●
Be sure to wait for 2 minutes before unplugging the power cord.
(The fan will continue to operate for about 2 more minutes after the unit is turned
off to cool down the heater.)
Room humidity control
●
The dehumidifying louver opens fully and the unit starts to
operate in “Medium” mode.
(The “Med” indicator and Humidity indicator light up.)
●
The indicator for the selected mode lights up.
●
When the room temperature rises above a certain level or when the temperature is low, the
airflow will increase automatically as a protective measure, causing the operating noise to
increase. (
page 25)
●
“Auto” mode will automatically control operation in order to maintain
a humidity of approximately 55%. (When the humidity becomes less
than 55%, the unit will switch to fan mode.)
Insert the power plug into
a wall socket.
●
Select the dehumidifying louver direction and air swing pattern
to point at the location you want to dry out.
(To adjust the air swing and louver directions
page 16, 17)
Press
Press
to choose the operating mode.
Press
and
to choose the air
swing pattern and
louver directions.
●
All indicators turn off.
●
You can use the timer to turn off the unit after a set time.
(To set the timer
page 19)
●
The fan will continue to operate for about 2 more minutes after
the unit is turned off to cool down the inside of the unit.
Press
To stop operation
To maintain a pleasant humidity
1
2
3
To dehumidify quickly
(strongest airflow)
To dehumidify normally
(medium airflow)
To dehumidify quietly
Important
Air Swing button
Power Off/On button
Louver Direction button
Dehumidity button and indicators