background image

2013.03

panasonic.net/id/pidsx/global

Amplifier Built-in Type Threaded 

Miniature Photoelectric Sensor

EX-30 Series

USER’S MANUAL

WUME-EX30-3

Summary of Contents for EX-30 Series

Page 1: ...2013 03 panasonic net id pidsx global Amplifier Built in Type Threaded Miniature Photoelectric Sensor EX 30 Series USER S MANUAL WUME EX30 3 ...

Page 2: ... interval 6 4 I O Circuit Diagram 8 5 Adjustment 9 5 1 Beam alignment Thru beam type EX 31 EX 33 9 5 2 Sensitivity adjustment Thru beam type EX 33 Diffuse reflective type EX 32 10 6 Stability Indicator 12 7 Option 13 7 1 Beam Slit Mask Thru beam type EX 31 EX 33 13 8 Specifications 14 9 Dimensions 15 ...

Page 3: ... a commercial switching regulator ensure that the frame ground F G terminal of the power supply is connected to an actual ground In case noise generating equipment switching regulator inverter motor etc is used in the vicinity of this product connect the frame ground F G terminal of the equipment to an actual ground Do not use during the initial transient time 50ms after the power supply is switch...

Page 4: ... side until it stops Note Use the flathead screwdriver please arrange separately to turn the operation mode switch slowly Turning with excessive strength will cause damage to the operation mode switch Emitter Receiver Emitter Sensitivity adjuster Sensing range becomes longer when turned clockwise Receiver Operation mode switch Beam axis Operation indicator Orange Output ON Lights up Stability indi...

Page 5: ...se the enclosed nut and toothed lock washer for mounting When the nut is tightened hold the the sensor with hand or a spanner etc and the tight ening torque should be 0 6N m or less diffuse reflective type EX 32 1N m or less Do not tighten the sensor itself Spanner Mounting plate Thick 3mm or less ...

Page 6: ...x 60 2mm according to left diagram The installation interval is Approx 60 2mm 2 approx 120 4mm Thus install EX 33 to approx 120 4mm or more away Installation interval for EX 32 In case using at sensing distance L3 50mm the op eration point ℓ3 is approx 9 1mm according to left diagram The installation interval is Approx 9 1mm 2 approx 18 2mm Thus install EX 32 to approx 18 2mm or more away Parallel...

Page 7: ...EX 33 Diffuse reflective type EX 32 EX 31 Approx 100 6mm or more EX 33 Approx 120 4mm or more EX 31 500mm EX 33 800mm EX 31 Approx 100 6mm or more EX 33 Approx 120 4mm or more Approx 18 2mm or more 50mm Approx 18 2mm or more ...

Page 8: ...ype Receiver of Thru beam type EX 31 PN EX 33 PN Diffuse reflective type EX 32 PN 12 to 24V DC 10 Color code Brown V Main circuit Blue 0V Users circuit Internal circuit Black Output Load 50mA max 12 to 24V DC 10 Main circuit Color code Brown V Blue 0V Users circuit Internal circuit Load 12 to 24V DC 10 Black Output 50mA max Main circuit Color code Brown V Blue 0V Users circuit Internal circuit ...

Page 9: ...witch to the L side Light ON mode position 2 Place the emitter and the receiver face to face along a straight line move the emitter in the up down left and right directions in order to determine the range of the light received condition with the help of the operation indicator orange Then set the emitter at the center of this range 3 Similarly adjust for up down left and right angular movement of ...

Page 10: ...ust er slowly clockwise and confirm the point A where the sensor enters the Light state operation 3 In the dark condition turn the sensitivity adjuster further clockwise until the sensor enters the Light state opera tion and then bring it back to confirm point B where the sensor just returns to the Dark state operation 4 The position at the middle of points A and B is the opti mum sensing position...

Page 11: ...nters the Light state opera tion and then bring it back to confirm point B where the sensor just returns to the Dark state operation If the sensor does not enter the Light state operation even when the sensitivity adjuster is turned fully clock wise the position is point B 4 The position at the middle of points A and B is the opti mum sensing position Note Use the flathead screwdriver purchase sep...

Page 12: ...able sensing can be done without the light received operation and the light interrupted operation being af fected by a change in ambient temperature or supply voltage Incident light margin Approx 15 Output operation level Output operation Operation of stability indicator Light up Light OFF Light received operation 0 0 100 Incident light intensity Setting distance Light interruption margin Approx 2...

Page 13: ...ng on both side Applying on one side Applying on both side Slit OS EX30 1 EX 31 ø1mm 200mm 150mm ø2mm ø1mm EX 33 320mm 240mm Mounting method 1 Insert the sensor into the mounting plate 2 Fit the washer and spacers enclosed with the slit mask Note that the number of spacers to be fitted differs with the mounting plate thickness as given in the table on the right 3 Mount the slit mask Make sure that...

Page 14: ...N Switchblade either Light ON or Dark ON Light ON Dark ON Short circuit protection Incorporated Response time 0 5ms or less Protection IP67 IEC Ambient temperature 25 to 55 C No dew condensation or icing allowed Storage 30 to 70 C Ambient humidity 35 to 85 RH Storage 35 to 85 RH Emitting element Red LED Material Enclosure Die cast zinc Nickel plated Enclosure cover Polycarbonate Lens Polycarbonate...

Page 15: ...3 Emitter and Receiver Unit mm 3 8 15 6 0 3 3 7 3 1 14 7 14 3 7 5 1 Opposing faces 7 thickness 2 4 Tooth lock washer ø8 5 M4 0 7 ø2 5 cable 2m Unit mm 15 6 0 3 3 7 3 1 14 7 14 3 7 5 1 3 8 M4 0 7 11 8 2 0 75 ø7 2 ø2 5 cable 2m Opposing faces 7 thickness 2 4 Tooth lock washer ø8 5 ...

Page 16: ...onal Unit mm 5 7 5 1 7 14 3 7 5 1 3 8 0 75 ø7 2 M6 0 75 ø2 5 cable 2m Unit mm ø4 3 ø8 1 Spacer Material POM Material Brass Nickel plated 5 3 7 8 02 ø1 Internal thread part M4 0 7 3 8 deep 0 3 Opposing faces 10 thickness 2 Tooth lock washer ø11 15 6 14 11 8 2 ...

Page 17: ...17 MEMO ...

Page 18: ...PRINTED IN JAPAN Overseas Sales Division Head Office 2431 1 Ushiyama cho Kasugai shi Aichi 486 0901 Japan Phone 81 568 33 7861 FAX 81 568 33 8591 About our sale network please visit our website Panasonic Industrial Devices SUNX Co Ltd 2013 WUME EX30 3 ...